CVF-U (Part Numbers)

Part Number

Configured Part Number is shown.

CVF-U-0.75SQ-4-0.5

Product features details

Structural outline

ConductorAnnealed copper composite stranded wire
InsulatorVinyl mixture
Pair strandWire cores twisted into a circular shape
TapeWound with multiple layers of tape
SheathLubricating urethane resin (black)

Operating Temperature Range

  • When working: 0 to 60°C

Technical information and design ideas

Technical Data

Cable typeIn Japan
Usable size-
Rated Voltage
Rated temperature60°C
Test voltage0.3, 0.5 mm^2: 1,000 V AC, 1min
0.75 to 2 mm^2: 3,000 V AC, 1 min
Flame Retardancy60° inclination
Compatible standard-

* The Electrical Appliances and Materials Safety Act of Japan does not apply to CVF-U, so please use it for low current circuits such as signal and communication circuits.

Standard Table

ConductorInsulationNumber of conductorsSheath outer diameter
(approx., mm)
Specifications of spring
Nominal cross-sectional areaOuter diameter
(approx., mm)
Outer diameter
(approx., mm)
Outer diameter of spring
(approx., mm)
Approximate weight
Per 1 m of spring (g)
0.3 mm^20.9
"3/20/0.08"
1.524.918180
35.119240
45.520290
66.625410
87.729550
109.134720
128.532740
169.636970
0.5 mm^21.2
"3/15/0.12"
2.025.922290
36.223360
46.926460
68.331650
89.736880
1011.7431,180
1211.0411,220
1612.5461,590
0.75 mm^21.4
"3/22/0.12"
2.627.327460
37.929590
48.632820
610.5391,080
813.3491,660
1014.5541,950
1214.9552,200
1616.5612,720
1.25 mm^21.7
"7/16/0.12"
2.928.130600
38.532750
49.535970
611.6431,460
814.6542,160
1015.9592,520
2 mm^22.1
"7/25/0.12"
3.329.134810
39.6361,020
410.7401,310

Product characteristics

Electrical Characteristics

ConductorNumber of conductorsElectrical Characteristics
Nominal cross-sectional areaAllowable current (A)Conductor resistance
20°C (Ω/km)
Insulation Resistance
20°C (MΩ/km)
0.3 mm^22262.3 or less5 or more
32
42
62
81
101
121
161
0.5 mm^22337.8 or less5 or more
33
43
62
82
102
122
162
0.75 mm^22425.1 or less5 or more
34
44
63
83
103
122
162
1.25 mm^22715.1 or less5 or more
37
47
64
84
103
2 mm^22109.79 or less5 or more
310
410

Allowable current

  • The allowable current values are calculated values at an ambient temperature of 30°C and when the cable is installed in a single line in the air, and are not guaranteed values.
  • If the ambient temperature is 30°C or higher, multiply the allowable current value by the current reduction factor shown in the table below.
  • The allowable current value is the value calculated by JCS0168, and it is not the guaranteed value.

JCS0168: Japanese Cable Makers' Association Standard "calculation of allowable current for power cables of 33 kV or less"

 

■Current reduction factor

Ambient temperature (°C)303540455055
Current reduction factor1.000.910.820.710.580.41

Wire Core Identification

Color-coding of wire cores for identification of Factory Automation, Highly Extendable Spring Cable, CVF-U Series

Structure

■Example: 6-core cable

Structural drawing of Factory Automation, Highly Extendable Spring Cable, CVF-U Series
  • Sheath outer diameter (d): As per the standard table.
  • Outer diameter of spring (D): The standard diameter is shown in the standard table (approx. 3.7 times the outer diameter of the cable).
  • Spring length (L): Standard lengths are 30, 50, 100, 150, and 200 cm.
  • Terminal length (l1/l2): The standard length is 30 cm.
  • Spring expansion/contraction: Please use the standard spring outer diameter with expansion and contraction within 3 times the length of the spring.

Drawing / external appearance example / mounting example

Mounting example

Mounting example of Factory Automation, Highly Extendable Spring Cable, CVF-U Series
Part Number
CVF-U-0.75SQ-4-0.5
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHS

1,092,060 IDR

1 Piece(s) 10 Day(s) or more 10

Loading...

  1. 1
 

Basic Information

Overall Length(m) 0.5 Conductor Cross Section(mm2) 0.75 Number Of Cores(Core) 4
Finished outer diameter(mm) 8.6 Rated Voltage For Low Current Circuits Shield NA
Properties Oil Resistance / Abrasion Resistance Sheath (outer coating) color Black Grounding Wire NA
Sheath (outer coating) material Lubricating urethane resin Insulation body materials PVC

Please check the type/dimensions/specifications of the part CVF-U-0.75SQ-4-0.5 in the CVF-U series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)