(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Electropneumatic regulator digital electropneumatic regulator EVD-3000 series (Part Numbers)

Electropneumatic regulator digital electropneumatic regulator EVD-3000 series

Compact, high-performance, digital regulation. Module type. Note: CAD data of this series is being revised. Please wait till the corrections are done.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
EVD-3100-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-3
EVD-3100-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[B3,​L3]-3
EVD-3100-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[C1,​C3,​P1,​P3]-3
EVD-3100-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[C1,​C3,​P1,​P3][B3,​L3]-3
EVD-3500-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-3
EVD-3500-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[B3,​L3]-3
EVD-3500-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[C1,​C3,​P1,​P3]-3
EVD-3500-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[C1,​C3,​P1,​P3][B3,​L3]-3
EVD-3900-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-3
EVD-3900-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[B3,​L3]-3
EVD-3900-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[C1,​C3,​P1,​P3]-3
EVD-3900-[0,​1,​2,​P][08,​10][AN,​AP,​SN,​SP]-[C1,​C3,​P1,​P3][B3,​L3]-3
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSupply Side, Connection Type Supply Side, Connection Dia. Pressure Control Range
(MPa)
Bracket Options (Added) Input specifications Option Output Types, Error Signals Power Supply Voltage

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.1NA0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitNA1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.1B Type / L type0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitNA1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.1NA0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitAnalog 9 Core, 1 m Cable / Analog 9 Core, 3 m Cable / Parallel 15 Core, 1 m Cable / Parallel 15 Core, 3 m Cable1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.1B Type / L type0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitAnalog 9 Core, 1 m Cable / Analog 9 Core, 3 m Cable / Parallel 15 Core, 1 m Cable / Parallel 15 Core, 3 m Cable1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.5NA0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitNA1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.5B Type / L type0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitNA1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.5NA0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitAnalog 9 Core, 1 m Cable / Analog 9 Core, 3 m Cable / Parallel 15 Core, 1 m Cable / Parallel 15 Core, 3 m Cable1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80–0.5B Type / L type0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitAnalog 9 Core, 1 m Cable / Analog 9 Core, 3 m Cable / Parallel 15 Core, 1 m Cable / Parallel 15 Core, 3 m Cable1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80~0.9NA0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitNA1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80~0.9B Type / L type0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitNA1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80~0.9NA0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitAnalog 9 Core, 1 m Cable / Analog 9 Core, 3 m Cable / Parallel 15 Core, 1 m Cable / Parallel 15 Core, 3 m Cable1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

-

1 Piece(s) 17 Day(s) or more Rc1/4 / 3/80~0.9B Type / L type0-10 VDC / 0-5 VDC / 4-20 mADC / Parallel 10-bitAnalog 9 Core, 1 m Cable / Analog 9 Core, 3 m Cable / Parallel 15 Core, 1 m Cable / Parallel 15 Core, 3 m Cable1 to 5 V Analog, Error (NPN) / 1 to 5 V Analog, Error (PNP) / Switch (NPN), Error (NPN) / Switch (PNP), Error (PNP)24 VDC

Loading...

  1. 1

Basic Information

Regulator, Pressure Boosting Valve Regulator Regulator Type Electropneumatic Applicable Fluid Air
Shape Standard Operating Environment Standard Exhaust Mechanism Presence
Adverse Current Function No Flow Direction Rightward direction Power Supply DC24V

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)