(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

FRL Units(Drain Cock:Automatic)

FRL Units, comprising filters, regulators, and lubricators, are integral components in pneumatic systems, designed to ensure clean, properly pressurized, and lubricated air supply to downstream equipment. Filters remove contaminants like water, oil aerosols, and solid particles, enhancing air quality. Regulators maintain consistent air pressure, preventing damage from fluctuations. Lubricators introduce a fine mist of oil into the air stream, reducing friction in moving parts and extending equipment life. Available in various configurations and materials to suit different environmental conditions and airflow requirements, FRL units are essential for improving the efficiency, reliability, and lifespan of pneumatic tools and machinery.
Days to Ship
  • All
  • Same day
  • 1 Day(s) or Less
  • 4 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  • 15 Day(s) or Less
  • 16 Day(s) or Less
  • 17 Day(s) or Less
  1. 1
Brand
Product Series
CAD
Days to Ship
Specifications
Regulator Unit Combination
Connection Dia.
Filter, Filtration Level
Compressed Air Quality
Max. Operating Pressure(MPa)
Relief Mechanism
Flow Direction
Drain Cock
Pressure Gauge

    Conditioning Equipment Multi Series, Filter Regulator FR Series

      [Stock] Filter Regulator (Modular Standard) W*000 Series

        Modular type FRL combination standard white series

          FRL Combination (Modular Type Standard) C*000/C*500 Series

            Modular type filter and regulator standard white series

              FR Combination (Modular Type Standard) C*020 / C2520 Series

                FMR Combination (Modular Type Standard) C*030/C2530 Series

                  FM Combination (Modular Type Standard) C*060 Series

                    Modular type WL combination standard white series

                      Modular type WM combination standard white series

                        Modular type reverse filter and regulator standard white series

                        Brand

                        KOGANEI

                        CKD

                        CKD

                        CKD

                        CKD

                        CKD

                        CKD

                        CKD

                        CKD

                        CKD

                        CKD

                        Product Series

                        Conditioning Equipment Multi Series, Filter Regulator FR Series

                        [Stock] Filter Regulator (Modular Standard) W*000 Series

                        Modular type FRL combination standard white series

                        FRL Combination (Modular Type Standard) C*000/C*500 Series

                        Modular type filter and regulator standard white series

                        FR Combination (Modular Type Standard) C*020 / C2520 Series

                        FMR Combination (Modular Type Standard) C*030/C2530 Series

                        FM Combination (Modular Type Standard) C*060 Series

                        Modular type WL combination standard white series

                        Modular type WM combination standard white series

                        Modular type reverse filter and regulator standard white series

                        CAD
                        • 2D
                        • 2D
                        • 2D / 3D
                        • 2D / 3D
                        • 2D
                        • 2D
                        • 2D
                        • 2D
                        • 2D
                        • 2D
                        Days to Ship 8 Day(s) or more 8 Day(s) or more 1 Day(s) or more 19 Day(s) or more 16 Day(s) or more 19 Day(s) or more 17 Day(s) or more 19 Day(s) or more 19 Day(s) or more 26 Day(s) or more 16 Day(s) or more
                        Specifications
                          • STOCK
                                            Regulator Unit CombinationFilter RegulatorFilter RegulatorFilter + Regulator + LubricatorFilter + Regulator + LubricatorFilter RegulatorFilter + RegulatorFilter + Micro Mist Filter + RegulatorFilter + Mist FilterFilter Regulator + LubricatorFilter Regulator + Mist FilterFilter Regulator
                                            Connection Dia.Rc1/4 / Rc3/8Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / Rc1Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / Rc1Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1/8 / G1/8 / G1/2 / G3/4Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / Rc1 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1/8 / NPT1 / G1/8 / G1/2 / G3/4 / G1Rc1/8 / Rc1/4 / Rc3/8 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/8 / G1/8Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / Rc1 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1 / G1/2 / G3/4 / G1Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / Rc1 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1/8 / NPT1 / G1/8 / G1/2 / G3/4 / G1Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1/8 / G1/8 / G1/2 / G3/4Rc1/4 / Rc3/8 / NPT1/4 / NPT3/8 / G1/4 / G3/8Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT1/8 / G1/8 / G1/2
                                            Filter, Filtration Level5µm5µm5µm0.3µm / 5µm0.3µm / 5µm0.3µm / 5µm0.3µm / 5µm0.3µm / 5µm0.3µm / 5µm5µm0.3µm / 5µm
                                            Compressed Air QualityGeneral Quality Dry Air / Clean Dry Air / Odorless AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry AirGeneral Quality Dry Air
                                            Max. Operating Pressure(MPa)0.931111111111
                                            Relief MechanismReliefReliefNon-Relief / ReliefNon-Relief / ReliefNon-Relief / ReliefNon-Relief / ReliefNon-Relief / Relief-Non-Relief / ReliefNon-Relief / ReliefNon-Relief / Relief
                                            Flow DirectionStandard Flow (Left to Right)Standard Flow (Left to Right)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)Standard Flow (Left to Right) / Reverse Flow (Right to Left)
                                            Drain CockAutomaticAutomaticAutomaticAutomaticAutomaticAutomaticAutomaticAutomaticAutomaticAutomaticAutomatic
                                            Pressure GaugeNone (Pressure Port Plug available)With Standard Pressure GaugeNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure GaugeNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure GaugeNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure SensorNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure SensorNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor-None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure GaugeNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure SensorNone (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor

                                            Loading...

                                            1. 1

                                            Related Categories to FRL Units