Control/Instrumentation Cables(Properties:Oil Resistance)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 8 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    UL Listed Unshielded Instrumentation Cable

      KVC-36SBT

        Twisted Pair Instrumentation Cable

          BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

            BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

              Sheathed Thermocouple Wire, FEP Flat Type Series

                Twisted Layer Instrumentation Cable

                  Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                    CL2/2464-3599-DS LF

                      HP-SB/20276SR LF

                        Instrumentation Cable, FKEV-SB

                        Brand

                        TACHII ELECTRIC WIRE

                        KURAMO ELECTRIC

                        TACHII ELECTRIC WIRE

                        BANDO DENSEN

                        BANDO DENSEN

                        DAIKO

                        TACHII ELECTRIC WIRE

                        NIHON ELECTRIC WIRE & CABLE

                        TAIYO CABLETEC

                        TAIYO CABLETEC

                        FUJI ELECTRIC WIRE INDUSTRIES

                        Product Series

                        UL Listed Unshielded Instrumentation Cable

                        KVC-36SBT

                        Twisted Pair Instrumentation Cable

                        BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                        BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                        Sheathed Thermocouple Wire, FEP Flat Type Series

                        Twisted Layer Instrumentation Cable

                        Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                        CL2/2464-3599-DS LF

                        HP-SB/20276SR LF

                        Instrumentation Cable, FKEV-SB

                        Days to Ship 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 12 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more
                        Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 10020 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 100
                        Specified Length(m)-----------
                        Conductor Cross Section(mm2)0.22 ~ 0.540.50.2 ~ 0.5---0.2 ~ 0.30.2 ~ 20.204 ~ 0.8230.08040.3 ~ 1.25
                        AWG size(AWG)20 ~ 242020 ~ 242224-22 ~ 2414 ~ 2418 ~ 2428-
                        Number Of Cores(Core)2 ~ 502 ~ 402 ~ 5010-22 ~ 402 ~ 60-4 ~ 402 ~ 20
                        Logarithm1P ~ 25P1P ~ 20P1P ~ 25P-17P1-1P ~ 30P1P ~ 5P2P ~ 20P1 ~ 10
                        Finished outer diameter(mm)4 ~ 154.8 ~ 164.6 ~ 15.97.112.40.8x1.2 ~ 1.6x2.84.6 ~ 11.65.5 ~ 285.1 ~ 144.2 ~ 7.55 ~ 20
                        Rated Voltage300VFor Low Current CircuitsOther300V300V-Other-For Low Current CircuitsFor Low Current CircuitsOther
                        ShieldNAAvailableAvailableNAAvailableNAAvailableAvailableAvailableAvailableAvailable
                        PropertiesOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil Resistance
                        Representative StandardUL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)-UL / CSA(c-UL)-UL / CSA(c-UL)UL-
                        Sheath (outer coating) colorBlackBlackGrayBlackBlackBrown / Yellow / BlueBlackBlackBlackBlackGray
                        Grounding WireNAOtherNA / Other--NAOtherNANANAOther
                        Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)-PVC (Polyvinyl Chloride)-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                        Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Fluorine-BasedPVC (Polyvinyl Chloride)Polyethylene-BasedPolyethylene-BasedPVC (Polyvinyl Chloride)Polyethylene-Based