Control/Instrumentation Cables(Logarithm:5P)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 8 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    Shielded Twisted Pair Multi-Core Cable, SPMC Series

      FCPEV Communication Cable

        UL Listed Unshielded Instrumentation Cable

          KVC-36SBT

            BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

              KPEV-SBT Series

                Twisted Pair Instrumentation Cable

                  BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                    Thick Multi-Pair Cable

                      KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

                        Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                          CL2/2464-3599-DS LF

                            HP-SB/20276SR LF

                              FCPEV (CU) Communication Cable

                              Brand

                              KANEKO CORD

                              FUJIKURA DIA CABLE

                              TACHII ELECTRIC WIRE

                              KURAMO ELECTRIC

                              BANDO DENSEN

                              NAGAOKA ELECTRIC WIRE

                              TACHII ELECTRIC WIRE

                              BANDO DENSEN

                              HITACHI CABLE

                              FUJI ELECTRIC CABLE

                              NIHON ELECTRIC WIRE & CABLE

                              TAIYO CABLETEC

                              TAIYO CABLETEC

                              FUJIKURA DIA CABLE

                              Product Series

                              Shielded Twisted Pair Multi-Core Cable, SPMC Series

                              FCPEV Communication Cable

                              UL Listed Unshielded Instrumentation Cable

                              KVC-36SBT

                              BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                              KPEV-SBT Series

                              Twisted Pair Instrumentation Cable

                              BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                              Thick Multi-Pair Cable

                              KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

                              Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                              CL2/2464-3599-DS LF

                              HP-SB/20276SR LF

                              FCPEV (CU) Communication Cable

                              Days to Ship 8 Day(s) or more 11 Day(s) or more 8 Day(s) or more 10 Day(s) or more 8 Day(s) or more 11 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 12 Day(s) or more 8 Day(s) or more 11 Day(s) or more 10 Day(s) or more 11 Day(s) or more
                              Overall Length(m)1 ~ 100500 ~ 10001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 200-1 ~ 10030 ~ 100100500 ~ 1000
                              Specified Length(m)---------100----
                              Conductor Cross Section(mm2)0.15-0.22 ~ 0.540.5-0.5 ~ 1.250.3 ~ 0.5-0.12 ~ 0.20.5 ~ 1.250.2 ~ 20.204 ~ 0.8230.0804-
                              AWG size(AWG)26-20 ~ 242020 ~ 2616 ~ 2020 ~ 2220 ~ 2624 ~ 2616 ~ 2014 ~ 2418 ~ 2428-
                              Number Of Cores(Core)10101010-1010-101010-1010
                              Logarithm5P5P5P5P5P5P5P5P5P5P5P5P5P5P
                              Finished outer diameter(mm)-10 ~ 117.4 ~ 9.49.27.1 ~ 10.411.5 ~ 15.48 ~ 10.16.5 ~ 9.8-11 ~ 15.58.5 ~ 198.3 ~ 145.18 ~ 10
                              Rated VoltageFor High VoltagesOther300VFor Low Current Circuits300VOtherOther300V300V--For Low Current CircuitsFor Low Current CircuitsOther
                              ShieldAvailableAvailableNAAvailableAvailableAvailableAvailableNAAvailableAvailableAvailableAvailableAvailableAvailable
                              Properties-WeatherproofOil Resistance / Heat-ResistanceOil ResistanceHeat-Resistance-Oil Resistance / Heat-ResistanceHeat-ResistanceHeat-Resistance-Oil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceWeatherproof
                              Representative Standard--UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)-UL / CSA(c-UL)UL / CSA(c-UL)UL--UL / CSA(c-UL)UL-
                              Sheath (outer coating) colorBlackBlackBlackBlackBlackBlackGrayBlackGrayBlackBlackBlackBlackBlack
                              Grounding WireNAOtherNAOther-OtherOther--NANANANAOther
                              Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)OtherPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                              Insulation body materialsPVC (Polyvinyl Chloride)Polyethylene-BasedPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)OtherPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-BasedPolyethylene-BasedPolyethylene-BasedPVC (Polyvinyl Chloride)Polyethylene-Based

                              Loading...

                              1. 1

                              Related Categories to Control/Instrumentation Cables