Earth Leakage Breakers (Low Capacity)(Ampere frame AF:30AF or less)

Earth Leakage Circuit Breakers (ELCB), also known as an earth leakage switch or earth leakage protector, is an electrical safety device that detects and protects against electrical shock hazards caused by leakage current. When selecting an Earth Leakage Circuit Breaker (ELCB), it is crucial to consider factors such as Ampere frame, Number of Poles, Rate Current, Rate Operating, Voltage, Mounting Method (e.g., DIN rail mount, Fasten with screws, and etc.), and Size (height , width and depth). These considerations are vital for ensuring the production of high-quality products. We highly recommend reputable brands like MITSUBISHI , FUJI ELECTRIC , and NITTO KOGYO
Take advantage of the convenience of FREE SHIPPING and NO MINIMUM ORDER on the Earth Leakage Circuit Breaker (ELCB). If you have any doubts or require assistance in choosing the right product, our experts are readily available to provide advice and guidance.
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 8 Day(s) or Less
  • 13 Day(s) or Less
  • 14 Day(s) or Less
  • 15 Day(s) or Less
  • 20 Day(s) or Less
  • 25 Day(s) or Less
  • 30 Day(s) or Less
  • 44 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Ampere frame AF
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Number of Poles
Rated Operating Voltage(V)
Rated Current(A)
rate sensitivity current(mA)
Mounting Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Connection Method

    Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges

      Earth Leakage Circuit Breakers (ELCB) NV-L Series

        Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA

          Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

            Earth Leakage Circuit Breakers (ELCB) NV-SV Series with CE/CCC

              Earth Leakage Circuit Breaker Supporting Higher Harmonic Surge (Standard Product), WS Series NV-F Type

                Earth Leakage Circuit Breakers (ELCB) NV-FA Series

                  Earth Leakage Circuit Breakers (ELCB) NV-KC Series with accessories

                    Circuit breaker for distribution board and control board KC series NV30-KC

                      Earth Leakage Circuit Breakers (ELCB) NV-SVF Series with CE/CCC

                        Circuit Breaker For Controlboard FAU Series (Earth Leakage Circuit Breaker) NV30-FAU

                          Earth Leakage Circuit Breakers (ELCB) NV32-SVF Series

                            Earth Leakage Circuit Breakers (ELCB) NV-FAU Series with accessories

                            Brand

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            Product Series

                            Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges

                            Earth Leakage Circuit Breakers (ELCB) NV-L Series

                            Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA

                            Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

                            Earth Leakage Circuit Breakers (ELCB) NV-SV Series with CE/CCC

                            Earth Leakage Circuit Breaker Supporting Higher Harmonic Surge (Standard Product), WS Series NV-F Type

                            Earth Leakage Circuit Breakers (ELCB) NV-FA Series

                            Earth Leakage Circuit Breakers (ELCB) NV-KC Series with accessories

                            Circuit breaker for distribution board and control board KC series NV30-KC

                            Earth Leakage Circuit Breakers (ELCB) NV-SVF Series with CE/CCC

                            Circuit Breaker For Controlboard FAU Series (Earth Leakage Circuit Breaker) NV30-FAU

                            Earth Leakage Circuit Breakers (ELCB) NV32-SVF Series

                            Earth Leakage Circuit Breakers (ELCB) NV-FAU Series with accessories

                            Days to Ship 5 Day(s) or more Same day or more Same day or more Same day or more 13 Day(s) Quote Same day or more Quote Quote Same day or more 13 Day(s) or more Quote Quote
                            Ampere frame AF30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less30AF or less
                            Rated block capacity AC 100 V(kA)101 ~ 1.51.5 ~ 2.57.5102.52.5557.52.57.52.5
                            Rated block capacity AC 200 V(kA)101 ~ 1.51.5 ~ 2.57.5102.52.5557.52.57.52.5
                            Rated block capacity AC 400 V(kA)5--55----5-5-
                            Number of Poles322 / 32 / 3332 / 3332 / 32 / 332
                            Rated Operating Voltage(V)100-440V ~ AC100 to 440AC100 ~ AC100-200AC100-200 ~ AC100 to 200AC100-440 ~ AC100 to 440AC100 to 440AC100 to 200100-200100 to 200AC100-200AC 100–240 ~ AC100 to 440AC100-240100-440100-240
                            Rated Current(A)20 ~ 3015 ~ 305 ~ 3010 ~ 3015205 ~ 1515 ~ 305 ~ 3020 ~ 3010 ~ 301015
                            rate sensitivity current(mA)30 ~ 50010 ~ 3015 ~ 3030 ~ 1003030303030303030 ~ 10030
                            Mounting MethodDIN rail mountFasten With ScrewsDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retentionDIN/Screw retention
                            Representative StandardPSEPSE / CE / TUVPSEPSE / CE / TUVPSE / CE / CCCPSE / CE / TUV / CCCPSEPSEPSEPSE / CE / TUV / CCCPSE / CE / TUV / CCCPSEPSE / CE / UL / CUL / TUV / CCC
                            Dimension height(mm)1307072100130727296961007210072
                            Dimension width(mm)753240 ~ 6036 ~ 54756040 ~ 60757536 ~ 5440 ~ 605440
                            Dimension depth(mm)9046.573.5909073.573.576769073.59073.5
                            Rated block capacity, voltages except VAC 100/200/400, VDC 250AvailableAvailable-Available------AvailableAvailableAvailable
                            Connection MethodSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface type