(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Molded Case Circuit Breakers (MCCB) NF-CVF Series with accessories

Molded Case Circuit Breakers (MCCB) NF-CVF Series with accessories

Mitsubishi low-voltage breaker contributing to building the future of electrical equipment.
Mitsubishi No-Fuse Breakers and Earth Leakage Circuit Breakers, meeting the needs of the market for over half a century.
Including the new WS-V series equipped with the latest breaker technology, various product ranges are available that address the needs of both the power incoming panel / distribution board market and machinery market.

PDF

Part Number

Configured Part Number is shown.

NF32-CVF 2P 10A

Product Specifications

Part NumberNF63-CVF
Rated current In
Standard ambient temperature 40°C A
(3)(5) 10
15 20 30
40 50
60(63)
Number of Positions232323
Rated insulation voltage Ui V440440440
Rating
Short circuit
Break
Capacity


kA
JIS C 8201-2-1 
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(lcu/lcs)
AC690 V---
500 V---
440 V2.5/2.52.5/2.52.5/2.5
415 V5/55/55/5
400 V5/55/55/5
380 V5/55/55/5
230 V7.5/7.57.5/7.57.5/7.5
DC
(*1)
250 V---
125 V---
GB 14048.2
(lcu/lcs)
AC415 V5/55/55/5
400 V5/55/55/5
380 V5/55/55/5
230 V7.5/7.57.5/7.57.5/7.5
DC
(*1)
250 V---
125 V---
Parts included as standard (Surface type)IEC 35 mm rail mounting clip
Insulation barrier (2-position 2 sheets, 3-position 4 sheets)

*(1) For 3-position products, use 2 positions.
Note (1) The mounting screws must be prepared by the customer. (Recommended size: M4 × 0.7 × 65 [2 pcs.])

 
Part NumberNF125-CVF
Rated current In
Standard ambient temperature 40°C A
60 75 100125
Number of Positions2323
Rated insulation voltage Ui V600600
Rating
Short circuit
Break
Capacity


kA
JIS C 8201-2-1 
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(lcu/lcs)
AC690 V--
500 V7.5/47.5/4
440 V10/510/5
415 V10/510/5
400 V10/510/5
380 V10/510/5
230 V30/1530/15
DC
(*1)
250 V7.5/47.5/4
125 V7.5/47.5/4
GB 14048.2
(lcu/lcs)
AC415 V10/510/5
400 V10/510/5
380 V10/510/5
230 V30/1530/15
DC
(*1)
250 V7.5/47.5/4
125 V--
Parts included as standard (Surface type)IEC 35-mm rail mounting clip
Insulation barrier (2-position 1 pc., 3-position 2 pcs.)
Mounting screw M4 × 0.7 × 55 (2 pcs.)

*(1) For 3-position products, use 2 positions.

Drawing

Drawing 01 of WS-V Series MCCB F Style NF-C Class (Economy Class)

NF63-CVF
Surface type
Note (1) Cables cannot be directly connected.
(2) The motor breaker has only 3 positions.

 
Drawing 02 of WS-V Series MCCB F Style NF-C Class (Economy Class)

NF125-CVF
Surface type

Part Number
NF32-CVF 2P 10A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAmpere frame Rated block capacity AC 200 V
(kA)
Rated Braking Capacity at Rated Voltage of VDC 250
(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current
(A)
Mounting Method Connection Method Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Type Internal included equipment Rated block capacity AC 415 V
(kA)
Rated block capacity AC 230 V
(kA)

850,833 IDR

1 Piece(s) Quote --2.5-210--PSE / CE / TUV / CCC1403665----

Loading...

  1. 1
 

Basic Information

Rated block capacity AC 400 V(kA) 5

Tech Support