(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Magnetic Contactors SD-T Series (Part Numbers)

SD-T Series Features

· Smaller width dimension:
Electromagnetic contactor sizes have been reduced for various ratings.

· Provided with a terminal cover as standard equipment:
By providing a terminal cover as standard equipment, the time for specifying a separate model name and ordering an option has been cut down, resulting in reduced inventory and cost for covers. It also improves safety by providing protections to the live parts.

· Noiseless direct current electromagnet:
This model directly applies the full voltage dedicated to direct current, which ensures a stabilized operation as it restricts the current using only the coil resistance, eliminating inrush current.

SD-T Series Specifications

TypeElectromagnetic contactor
Product (Electromagnetic Contactor)Irreversible electromagnetic contactor
SeriesSD-T
Reversible OperationNot possible (irreversible)
Operating CoilOperating Voltage TypeDirect current
PropertiesPower Consumption*9 W (SD-T35/T35SA/T35BC/T50)
18 W (SD-T65/T80)
24 W (SD-T100)
Coil Current90 mA (SD-T35/T35SA/T35BC/T50)
180 mA (SD-T65/T80)
240 mA (SD-T100)
Coil Time Constant*40 ms (SD-T35/T35SA/T35BC/T50)
65 ms (SD-T65/T80)
80 ms (SD-T100)
Surge Absorption for Operating CoilSD-T35SA
N/AOther than the above
Terminal CoverProtective Cover for Live PartsSD-T35/T35SA/T35BC/T50
N/ASD-T65/T80/T100
Terminal With Streamlined Wiring FunctionSD-T35BC
N/AOther than the above
Product Mounting MethodScrew / DIN rail (SD-T35/T35SA/T35BC/T50)
Screw (SD-T65/T80/T100)
Main Circuit Voltage200 to 220 V AC, 380 to 440 V AC, 500 to 550 V AC

*Values shown in Operating Coil’s Power Consumption and Time Constant are the average values.

SD-T35/SD-T50 Specifications

Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T35/SD-T50 external appearance

Weight: 0.85 kg

Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T35/SD-T50 dimensional drawing

  1. *1Dimension: with a front-clip-on auxiliary contact unit (UT-AX2 [BC], UT-AX4 [BC]).
  2. *2Dimension: measured from center of IEC 35 mm-wide rail.
  3. *3Dimension: with one side-mounted auxiliary contact unit (UT-AX11[BC]).
  4. *4Dimension: with two side-mounted auxiliary contact units (UT-AX11 [BC]) (on both sides).
Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T35/SD-T50 dimensional drawing

Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T35/SD-T50 contact configuration

SD-T65/SD-T80 Specifications

Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T65/SD-T80 external appearance

Weight: 2.1 kg

Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T65/SD-T80 dimensional drawing

  1. *1Dimension: with a front-clip-on auxiliary contact unit (UN-AX2, UT-AX4).
  2. *2Dimension: with one side-mounted auxiliary contact unit (UN-AX11).
  3. *3Dimension: with two side-mounted auxiliary contact units (UN-AX11) (on both sides).
Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T65/SD-T80 dimensional drawing

Electromagnetic contactor SD-T (irreversible) DC operation type: related images

SD-T65/SD-T80 contact configuration

  • *Please see the catalog for specifications of other part numbers.
Part Number
SD-T12 DC24V
SD-T20 DC24V
SD-T21 DC24V
SD-T35 DC24V
SD-T35BC DC24V
SD-T35SA DC24V
SD-T50 DC24V
SD-T65 DC24V
SD-T80 DC24V
SD-T100 DC24V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSAuxiliary Contact Dimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)
Mechanical opening and closing durability
(x10K times)
Frame Size Rated current used Three-phase box motor (AC-3) AC 200 to 220 V
(A)
Rated current used Three-phase box motor (AC-3) AC 380 to 440V
(A)
Rated current used Three-phase box motor (AC-3) AC 500 to 550V
(A)

771,833 IDR

1 Piece(s) Quote 102a2b754310010000T121399

1,016,500 IDR

1 Piece(s) Same day -1a1b75431001000T20181817

1,050,333 IDR

1 Piece(s) Same day -2a2b81631081000T21202017

1,577,333 IDR

1 Piece(s) Same day -2a2b89751231000T35353226

1,897,333 IDR

1 Piece(s) Quote -2a2b89751231000T35353226

1,822,166 IDR

1 Piece(s) Same day -2a2b89751231000T35353226

1,803,333 IDR

1 Piece(s) Quote -2a2b89751231000T50504838

2,913,833 IDR

1 Piece(s) Quote -2a2b10688133500T65656545

3,456,000 IDR

1 Piece(s) Quote -2a2b10688133500T80808075

4,065,833 IDR

1 Piece(s) Quote -2a2b134100157500T1001009375

Loading...

  1. 1
 

Basic Information

Operating Method Irreversible type Coil rated voltage(V) DC24V Specifications DC operation

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)