(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
This translation is a Google translation Terjemahan ini adalah terjemahan Google
Mitsubishi thermal relay TH-T series.
[Features]
・ ncredible performance housed in a small body.
・ The even more advanced version of the Mitsubishi Electric electromagnetic opening/closing device.
・ Can be used to detect motor overload and locked rotor current.
・ Product lineup containing overload short circuit protection, time lag and accelerated types for every application.
[Applications]
・ Motor burnout protection.
Part Number
Configured Part Number is shown.
TH-T18KP 15A
Applicable to motor protection: can be used for standard motor overload and locking protection.
Easy current value setting: can directly set the motor current value. Adjust with a cross-head / straight-slot screwdriver.
Reset method change: easy to change between manual reset and automatic reset.
With 1a1b contact: can use different voltages for a and b contacts.
Terminal cover as standard equipment (TH-T18/TH-T50): Having a terminal cover as standard equipment reduces the time for customers to specify a separate model name or arrange for options. This reduces inventory and reduces cover costs. Safety has also improved for protecting the live parts.
Outline drawing
Contact Configuration
For combining with the following electromagnetic contactors.
TH-T18:S-T10, T12, T20 SD-T12, T20
Can use as single unit in combination with single unit mounting unit UT-HZ18.
Outline drawing
Contact Configuration
Cannot be used with single unit mounting.
Use the following connection conductor (sold separately) when combining with an electromagnetic contactor.
Combination with S-T35/T50 (BC), SD-T35/T50 (BC): UT-TH50
Outline drawing
Contact Configuration
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Combination with S (D) -T65/T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352
Outline drawing
Contact Configuration
Cannot be used with single unit mounting.
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Connection conductor kit (sold separately, model name: BH569N350) used
Combination with S (D) -T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352
Part Number |
---|
TH-T18KP 15A |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Motor capacity/nominal thermal nominal size 440 VAC (kW/A) | Motor Capacity / Thermal Nominal Size VAC 220 (kW/A) | Coil rated voltage (V) | Auxiliary Contact | Representative Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Frame Size | Finger protection/terminal cover | Nominal heater size (A) | Nominal heater size (A) | Settling current adjustment range (A) | Rated insulation voltage (V) | Rate Impulse voltage resistant (kV) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V (A) | Application | Terminal screw size (main circuit/operating circuit) | Trip class | Trip free | Reset method | Operation display (lever display) | Manual trip check |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
429,170 IDR | 1 Piece(s) | 5 Day(s) | 3.7 | 7.5 | 690 | - | CE / CUL / TUV / CCC | 55 | 46 | 76.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Loading...
Please check the type/dimensions/specifications of the part TH-T18KP 15A in the Overload Relays TH-T Series series.
Part Number |
---|
TH-T100KP 67A |
TH-T100KP 82A |
TH-T18 0.12A |
TH-T18KP 2.1A |
TH-T18KP 2.5A |
TH-T18KP 3.6A |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Motor capacity/nominal thermal nominal size 440 VAC (kW/A) | Motor Capacity / Thermal Nominal Size VAC 220 (kW/A) | Coil rated voltage (V) | Auxiliary Contact | Representative Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Frame Size | Finger protection/terminal cover | Nominal heater size (A) | Nominal heater size (A) | Settling current adjustment range (A) | Rated insulation voltage (V) | Rate Impulse voltage resistant (kV) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V (A) | Application | Terminal screw size (main circuit/operating circuit) | Trip class | Trip free | Reset method | Operation display (lever display) | Manual trip check |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
749,170 IDR | 1 Piece(s) | 5 Day(s) | - | - | - | 1a1b | - | 73.5 | 89 | 83.5 | 3 elements (2E) | T100 | NA | - | 67 | 54~80 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.5/1 | 1 | 0.2 | 0.1 | For electromagnetic switch | M6/M4 | 10 | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
749,170 IDR | 1 Piece(s) | Same day | - | - | - | 1a1b | - | 73.5 | 89 | 83.5 | 3 elements (2E) | T100 | NA | - | 82 | 65~100 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.5/1 | 1 | 0.2 | 0.1 | For electromagnetic switch | M6/M4 | 10 | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
263,500 IDR | 1 Piece(s) | Same day | - | - | - | 1a1b | - | 55 | 45 | 76.5 | Standard/2 elements | T18 | Standard equipment | - | 0.12 | 0.1~016 | 690 | 6 | 2/2 | 2/2 | 1/1 | 0.3/0.3 | 0.5 | 0.2 | 0.1 | For electromagnetic switch | M3.5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
406,670 IDR | 1 Piece(s) | Same day | 0.4 | - | 690 | - | CE / CUL / TUV / CCC | 55 | 46 | 76.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
406,670 IDR | 1 Piece(s) | 5 Day(s) | - | 1.1 | 690 | - | CE / CUL / TUV / CCC | 55 | 46 | 76.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
406,670 IDR | 1 Piece(s) | 5 Day(s) | 0.75 | 1.5 | 690 | - | CE / CUL / TUV / CCC | 55 | 46 | 76.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
How can we improve?Bagaimana Kami bisa meningkatkan Pelayanan?
How can we improve?Bagaimana Kami bisa meningkatkan Pelayanan?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy Walaupun Kami tidak dapat langsung menjawab saran yang ditulis di lembar ini, informasinya akan kami review untuk peningkatan pelayanan dikemudian hari
Kebijakan Privacy
Thank you for your cooperation.Terima kasih atas kerjasama anda.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy Walaupun Kami tidak dapat langsung menjawab saran yang ditulis di lembar ini, informasinya akan kami review untuk peningkatan pelayanan dikemudian hari
Silahkan pergunakan Forms Permintaan.
Kebijakan Privacy