Serial Communication Unit CJ1W-SCU

Serial Communication Unit CJ1W-SCU Specifications of OMRON PLC

Serial communication unit CJ1W-SCU: Related images

PLC Appearance of Model CJ1W-SCU22/Model CJ1W-SCU21-V1/SCU31-V1/SCU41-V1

Note: Appearance may vary depending on model.

Serial communication unit CJ1W-SCU: Related images

PLC Appearance of the CJ1W-SCU32

Serial communication unit CJ1W-SCU: Related images

PLC Appearance of the CJ1W-SCU42

Serial communication unit CJ1W-SCU: Related images

PLC Model CJ1W-SCU22 / Model CJ1W-SCU21-V1 / SCU31-V1 / SCU41-V1 dimensional diagram (unit: mm)

Serial communication unit CJ1W-SCU: Related images

PLC Model CJ1W-SCU32 dimensional drawing (unit: mm)

Serial communication unit CJ1W-SCU: Related images

PLC Model CJ1W-SCU42 dimensional drawing (unit: mm)

Features of PLC

  • It is also possible to connect an RS-232C/RS-422A conversion unit (NT-AL001) to the RS-232C port to enable 1:N communication.
  • The CJ1W-SCU□2 model enables connection to high-speed external devices by improving communication speeds (up to 230.4 kbps) and reducing data transfer times to the CPU unit.

System Configuration Diagram of OMRON PLC

Serial communication unit CJ1W-SCU: Related images

CJ1W-SCU system configuration diagram

Kinds of OMRON PLC

About overseas standards

  • The symbols are as follows: UC1: cULus (Class I Div 2 hazardous location certified product), N: NK, L: Lloyd.
  • Please contact our support center for information on terms of use.
Unit TypeProduct NamespecificationNumber of occupied unitsCurrent consumption (A)formatInternational Standards
Communication Interface SectionCommunication features5V system
CJ1
CPU
High Performance
Unit
Serial
communication
unit
high speed type
RS-232C x 2 portsIn the CJ system, the following functions can be selected for each port
: Protocol macro
, Host link
, NT link (1:N mode)
, Serial gateway
, No procedure
, Modbus-RTU slave

In the NJ system, the following functions can be selected for each port
: Protocol macro
, Serial gateway
, No procedure *3
, Modbus-RTU slave
Unit 10.28 *1Model CJ1W-SCU22 *2UC1, N, L
RS-422A/485 x 2 ports0.40Model CJ1W-SCU32 *2UC1, N, L, CE
RS-232C x 1 port
RS-422A/485 x 1 port
0.36 *1Model CJ1W-SCU42 *2
CJ1
CPU
High Performance
Unit
Serial
Communication
Unit
RS-232C x 2 portsThe following functions can be selected for each port
: Protocol macro *4
, Host link
, NT link (1:N mode)
, Serial gateway *5
, Non-procedure *6
, Modbus-RTU slave *7
Unit 10.28 *1Model CJ1W-SCU21-V1 *8UC1, N, L
RS-422A/485 x 2 ports0.38Model CJ1W-SCU31-V1 *8UC1, N, L, CE
RS-232C x 1 port
RS-422A/485 x 1 port
0.38 *1Model CJ1W-SCU41-V1 *8UC1, N, L
  • *1When using the RS-232C/RS-422A conversion unit NT-AL001, the current will increase by 0.15 A per unit.
  • *2. The simple backup function and interrupt notification function cannot be used with the NJ system.
  • *3 . The SerialRcvNoClear instruction is available only for Serial Communication Unit version 2.1 or later, NJ-series CPU Unit version 1.03 or later, and Sysmac Studio version 1.04 or later.
  • *4The protocol macro trace function works when the CPU unit is in run/monitor mode. (NJ-series CPU units do not have a monitor mode.)
  • *5. The serial gateway function is only available for serial communication units version 1.2 or later.
  • *6 . The non-procedure function is only available for serial communication units with version 1.2 or later. (The CPU unit must also be version 3.0 or later.)
  • *7. The Modbus-RTU slave function is only available for serial communication units version 1.3 or later.
  • *8This unit cannot be used with the NJ-series Machine Automation Controller.

Serial Communication Unit AccessorOMRON ies

formataccessoriesspecification
Model CJ1W-SCU32Serial port (RS-422A/485) connector x 2Terminal block connector (FMC1.5/5-STF-3.5AU) manufactured by Phoenix Contact
Model CJ1W-SCU42Serial port (RS-422A/485) connector x 1Terminal block connector (FMC1.5/5-STF-3.5AU) manufactured by Phoenix Contact

Note: The serial port (RS-232C) connector is not included. If you are using a serial port, please also purchase a serial port connector.
Plug: XM3A-0921 or equivalent
Hood: XM2S-0911-E or equivalent

Implementable Devices of OMRON PLC

formatNJ SystemCJ System (CJ1, CJ2)CP1H SystemNSJ Systems
CPU rack *4Expansion rack *4CPU unitAdditional EquipmentCP1H main unitNSJ Main UnitAdditional Equipment
Model CJ1W-SCU22Unit Ver.2.010 units10 units
(per additional rack)
10 units *110 units *2
(per additional device)
2 units *3No10 units *2
(per additional device)
Model CJ1W-SCU32Unit Ver.2.0
Model CJ1W-SCU42Unit Ver.2.0
Model CJ1W-SCU21-V1Unit Ver.1.3No
Model CJ1W-SCU31-V1Unit Ver.1.3
Model CJ1W-SCU41-V1Unit Ver.1.3

Note: The number of units that can be installed in one device may be less than the above number depending on the current consumption of the other installed units.

  • *1 . This applies when using a CJ2H CPU Unit (without EtherNet/IP function) CJ2H-CPU6@ and a Power Supply Unit CJ1W-PA205@ or CJ1W-PD025@ (when not using NT-AL001).
  • *2. This is the number when using the CJ1W-PA205□ or CJ1W-PD025 power supply unit.
  • *3. Requires CJ-Unit Adapter CP1W-EXT01.
  • *4. A total of 16 units including any other CPU high-performance units that may be installed.

Specification Table of OMRON PLC

Controller SeriesCJ Series
Product nameSerial Communication Unit
Unit TypeCPU high-performance unit
formatModel CJ1W-SCU22Model CJ1W-SCU32Model CJ1W-SCU42Model CJ1W-SCU21-V1Model CJ1W-SCU31-V1Model CJ1W-SCU41-V1
Serial Communication PortPort 1RS-232CRS-422A/485RS-422A/485RS-232CRS-422A/485RS-422A/485
Port 2RS-232CRS-422A/485RS-232CRS-232CRS-422A/485RS-232C
protocolPort 1Host link, protocol macro, serial gateway, no procedure,
NT link, Modbus-RTU slave, loopback test, or host link
1:1 procedure mode can be selected for each port *1 *2
Either host link, protocol macro, NT link or loopback test can be selected for each port.-
Unit version 1.2 and later also supports serial gateway, no procedure and host link 1:1 procedure *1
. Unit version 1.3 and later supports Modbus-RTU slave mode.
Port 2
CPU unitA maximum of 16 units in total including other installed CPU Bus UnitsNo
restrictions on installation locationHowever
, when using external interrupt tasks, the unit must be installed in one of the following slots on the CPU device.
-When installed in a CJ2H-CPU6@-EIP: slots 0 to 3
-When installed in a CJ2H-CPU6@, CJ2M-CPU@@, or CJ1G/H-CPU@@H: slots 0 to 4
-When installed in a CJ1M-CPU@@: slots 0 to 2If
installed in any other slot, the external interrupt task will not start.
With other CPU high-performance units installed, a maximum of 16 units
can be installed. No restrictions on installation position.
Additional Equipment
Data exchange with the CPU unitSoft switch and constant status refreshOccupies 25CH out of 25CH in the CPU high-performance unit relay area (always exchanges data with the CPU unit)
Transferring system settings from the CPU UnitOccupies 10CH (total 20CH) per serial port in the CPU high-performance unit DM area.
Data transfer from the CPU unit,
power ON, restart
, ladder (STUP) command
, and system setting change (AR area) OFF→ON at the following times.
Simple backup functionThe CPU Unit's simple backup operation allows protocol macro data in the Serial Communications Unit to be backed up to a memory card, restored, and verified (only when using CJ2/CJ1-H/CJ1M CPU Units).
Current consumption *3280mA+x400mA360mA+x280mA+x380mA380mA+x
massUnder 160gUnder 120gUnder 140gUnder 110gUnder 110gUnder 110g
  • *1Serial Gateway: The serial gateway function can be executed even in protocol macro mode.
  • *2Non-protocol: An external interrupt task can be started when receiving data without procedure. When combined with a CJ2 CPU Unit version 1.1 or later or a CJ2M CPU Unit, high-speed non-protocol (DRXDU/DTXDU instructions) is possible.
  • *3. Current consumption for the serial communications unit alone.
    When using the NT-AL001, power is supplied to the NT-AL001 from the serial communications unit. When using the NT-AL001
    , the current consumption increases by 0.15 A for each NT-AL001.
    The current consumption value differs for each unit. Please be careful when replacing units.
    x: 0.15 A is added per port for the 5 V power supplied from the RS-232C port to the NT-AL001.

External Interface of OMRON PLC

External interfaces include an RS-232C port and an RS-422A/485 port.

Serial communication unit CJ1W-SCU: Related images

PLC External interface for CJ1W-SCU21-V1/SCU22

Serial communication unit CJ1W-SCU: Related images

PLC External interface for CJ1W-SCU41-V1

Serial communication unit CJ1W-SCU: Related images

PLC External interface for CJ1W-SCU42

*Only some product information is listed.

Part Number
CJ1W-SCU32
CJ1W-SCU42
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSCommunication Interface (Transmission Standard) Current Consumption
(A)

13,985,325 IDR

1 Piece(s) 8 Day(s) or more 10RS-422(A)/4850.40

22,964,290 IDR

1 Piece(s) 8 Day(s) -RS-232 / RS-422(A)/4850.36

Loading...

  1. 1
 

Basic Information

Number of Ports 2 Representative Standard CE / UL / CUL / CSA Number of Serial Numbers 1 unit's worth