(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 24/11/2024 sampai dengan 6:00 pada tanggal 25/11/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 24/11/2024 to 6:00 (WIB) 25/11/2024. We apologize for the inconvenience.
  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Safety/Relay Unit G9SA (G9SB-3012-A AC/DC24)

Safety/Relay Unit G9SA G9SB-3012-A AC/DC24
  • On Sale Till 31/03/2025

Safety relay unit G9SA

[Features]
· Small size, with an abundant series.
· 45 mm width, with an abundant variety of 3-pole. 5-pole, 3-pole + off delay 2-pole, 2 hand controllers.
· We also offer 17.5 mm width 3-pole, off delay 3-pole expansion units.
· Expansion units can be connected with a single action.
· Off delay types can be set at 15 different time levels.
· Certified ENISO13849-1 (PLe/Safety Category 4).
· Can be DIN rail mounted or screw mounted.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

G9SB-3012-A AC/DC24

Safety Relay Unit G9SA Specifications

Main ContactAuxiliary ContactNumber of Input ChannelsRated VoltageFormat
3 a1 b1 ch and 2 ch shared24 V AC/DCModel G9SA-301
100 to 240 V AC
5 a24 V AC/DCModel G9SA-501
100 to 240 V AC

Emergency stop unit

Main ContactOFF Delay
Contact
Auxiliary ContactNumber of Input ChannelsOFF Delay
Time
Rated VoltageFormat
3 a2 a1 b1 ch and 2 ch
shared
7.5 secs24 V AC/DCModel G9SA-321-T075
15 secs24 V AC/DCModel G9SA-321-T15
30 secs24 V AC/DCModel G9SA-321-T30

Emergency stop unit with OFF delay
The OFF delay time is variable in 15 steps. The following times can be set:
T075: 0.5/1/1.5/2/2.5/3/3.5/4/4.5/5/5.5/6/6.5/7/7.5 secs
T15: 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15 secs
T30: 2/4/6/8/10/12/14/16/18/20/22/24/26/28/30 secs

Safety Relay Unit G9SB Specifications

Main ContactAuxiliary ContactNumber of Input ChannelsReset ModeInput TypeRated VoltageFormat
2 aNone2 chAutoInverse24 V AC/DCModel G9SB-2002-A
1 ch, 2 chPositive CommonModel G9SB-200-B
2 chManualInverseModel G9SB-2002-C
1 ch, 2 chPositive CommonModel G9SB-200-D
3 a1 bNo (Power supply directly OFF)Auto--24 V DCModel G9SB-3010
2 chInverse24 V AC/DCModel G9SB-3012-A
1 ch, 2 chPositive CommonModel G9SB-301-B
2 chManualInverseModel G9SB-3012-C
1 ch, 2 chPositive CommonModel G9SB-301-D
  • The inverse input type is mainly used for mechanical switch 2-ch input.
  • The positive common input type is mainly used for safety sensor input or for mechanical switch 1-ch input.
  • *The Model G9SB-3010 can be applied to safety category 3 because of its power supply double break.

Rating

FormatModel G9SA-301Model G9SA-501Model G9SA-321-T□
Power Supply Voltage24 V AC/DC: 24 V AC, 50/60 Hz / 24 V DC, 100 to 240 V AC: 100 to 240 V AC, 50/60 Hz
Allowable Voltage Fluctuation RangePower supply voltage -15% +10%
Power Consumption24 V AC/DC: 1.8 VA/1.7 W max.
100 to 240 V AC: 9 VA max.
24 V AC/DC: 2.8 VA/2.6 W max.
100 to 240 V AC: 11 VA max.
24 V AC/DC: 3.5 VA/3.3 W max.
100 to 240 V AC: 12.5 VA max.

Power supply: G9SA type

  • *Increases by a maximum of 2 VA / 2 W when an expansion unit is connected.
FormatModel G9SB-200□-□Model G9SB-3010Model G9SB-301□-□
Power Supply Voltage24 V AC/DC: 24 V AC, 50/60 Hz / 24 DC, 24 V DC: 24 V DC
Allowable Voltage Fluctuation RangePower supply voltage -15% +10%
Power Consumption1.6 VA / 1.4 W max.1.7 W max.2.0 VA / 1.7 W max.

Power supply: G9SB type

FormatModel G9SA-301/321-T□Model G9SA-501
Input Current40 mA max.60 mA max.

Input: G9SA type

  • *Increases by a maximum of 30 mA when an expansion unit is connected.
FormatModel G9SB-200□-□Model G9SA-3010Model G9SB-301□-□
Input Current25 mA max.60 mA max.30 mA max.

Input: G9SB type

FormatModel G9SA-301/501/321-T□
LoadResistive Load
Rated Load250 V AC 5 A, 30 V DC 5 A
Rated Carry Current5 A

Switch: G9SA type

FormatModel G9SB-200□-□, Model G9SB-3010, Model G9SB-301□-□
LoadResistive Load
Rated Load250 V AC 5 A, 30 V DC 5 A
Rated Carry Current5 A

Switch: G9SB type

Performance

FormatModel G9SA-301Model G9SA-501/321-T□
Contact Resistance100 mΩ
Operating Time30 ms max.
Response Time10 ms max.
Insulation Resistance100 MΩ min., 500 V DC ohmmeter
Dielectric StrengthBetween Different Outputs2,500 V AC 50/60 Hz 1 min
Between Input and Output
Between Power Supply and Output
Between Power Supply and Input (100 to 240 V AC only)
Vibration Resistance10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock ResistanceDurability300 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical100,000 operations min. (at 1,800 operations/hr under rated load)
Failure Rate (P Level) (Reference Value)5 V DC 1 mA
Ambient Operating Temperature-25 to +55°C (assuming no icing or condensation)
Ambient Operating Humidity35 to 85% RH
Terminal Tightening Torque0.98 N·m
WeightApprox. 210 gApprox. 270 g
  • Measured with 1 A at 5 V DC using the voltage-drop method.
  • Not Including bounce time.
  • The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
  • Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
  • The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
  • The weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.
FormatModel G9SB-200□-□Model G9SB-3010Model G9SB-301□-□
Contact Resistance100 mΩ
Operating Time30 ms max.
Response Time10 ms max.
Insulation Resistance100 MΩ min., 500 V DC ohmmeter
Dielectric StrengthBetween Different Outputs2,500 V AC 50/60 Hz 1 min
Between Input and Output
Between Power Supply and Output
Vibration Resistance10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock ResistanceDurability300 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical100,000 operations min. (at 1,800 operations/hr under rated load)
Failure Rate (P Level) (Reference Value)5 V DC 1 mA
Ambient Operating Temperature-25 to +55°C (assuming no icing or condensation)
Ambient Operating Humidity35 to 85% RH
Terminal Tightening Torque0.5 N·m
WeightApprox. 115 gApprox. 135 gApprox. 120 g
  • Measured with 1 A at 5 V DC using the voltage-drop method.
  • Not Including bounce time.
  • The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
  • Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
  • The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
"m-h3--wysiwyg">Product dimensional outline drawings

Units: mm

 
Model G9SA-301, Model G9SA-501, Model G9SA-321-T□ full view

Model G9SA-301
Model G9SA-501
Model G9SA-321-T□ full view

Model G9SA-301, Model G9SA-501, Model G9SA-321-T□ dimensional outline drawing

Dimensional outline drawings

  • Time switch is only available for the Model G9SA-321-T□.
  • The K1 to K4 LEDs light when the a contacts of internal relays K1 to K4 close.
  • *Do not remove unless an expansion unit is being used.

Units: mm

Model G9SB-200□-□, Model G9SB-3010 full view

Model G9SB-200□-□
Model G9SB-3010 full view

Model G9SB-200□-□, Model G9SB-3010 dimensional outline drawing

Dimensional outline drawings

Units: mm

Model G9SB-301□-□ full view

Model G9SB-301□-□ full view

Model G9SB-301□-□ dimensional outline drawing

Dimensional outline drawings

Part Number
G9SB-3012-A AC/DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSContact Configuration Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Classification Off delay time
(Second)
Rated Voltage
(V)
Reset Mode Input Type

3,042,690 IDR

1 Piece(s) 8 Day(s) or more -[Other] 3a1bCE / UL / TUV / CCC / CSA10023112Emergency Stop Unit-AC/DC24AutoInverse

Loading...

  1. 1
 

Basic Information

Application Safety relay Latch function NA Terminal shape Screw Fastening

Please check the type/dimensions/specifications of the part G9SB-3012-A AC/DC24 in the Safety/Relay Unit G9SA series.

Products like this...

Part Number
G9SA-301 AC100-240
G9SA-321-T075 AC/DC24
G9SA-321-T15 AC/DC24
G9SA-321-T30 AC/DC24
G9SA-501 AC/DC24
G9SB-3012-C AC/DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSContact Configuration Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Classification Off delay time
(Second)
Rated Voltage
(V)
Reset Mode Input Type

5,048,571 IDR

1 Piece(s) 8 Day(s) or more -[Other] 3a1bCE / UL / CCC / CSA7645111Emergency Stop Unit-AC100-240--

7,171,429 IDR

1 Piece(s) 8 Day(s) or more 10[Other] 3a2a1bCE / UL / CCC / CSA7645111Emergency Stop Unit - With OFF Delay7.5AC/DC24--

5,754,240 IDR

1 Piece(s) 8 Day(s) or more 10[Other] 3a2a1bCE / UL / CCC / CSA7645111Emergency Stop Unit - With OFF Delay15AC/DC24--

5,754,240 IDR

1 Piece(s) 8 Day(s) or more 10[Other] 3a2a1bCE / UL / CCC / CSA7645111Emergency Stop Unit - With OFF Delay30AC/DC24--

6,057,143 IDR

1 Piece(s) 8 Day(s) or more 10[Other] 5a1bCE / UL / CCC / CSA7645111Emergency Stop Unit-AC/DC24--

3,042,233 IDR

1 Piece(s) Same day 10[Other] 3a1bCE / UL / TUV / CCC / CSA10023112Emergency Stop Unit-AC/DC24ManualInverse

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)