(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
This translation is a Google translation Terjemahan ini adalah terjemahan Google
[Features]
· Simplifies operation of one day schedule control.
· Can select operation weekday (however, only one each of operational weekday and special weekday can be set).
· ON/OFF time schedule setting has 24 steps.
· Compatible with the CE mark.
· UL, CSA standard acquired.
· Remarkably simple handling of bank holidays with holiday function.
· Simplified checking of the program with the test mode function.
· Can deal with urgent schedule changes with the semiautomatic operation.
· Pulse operation enabled as well as Summer time response.
· All functions subject to finger protection.
· A line-up of convention dimension types which are surface or deep mounted.
· Day-to-day operations are possible with the same settings as timer operation.
Japanese Only
Part Number
Configured Part Number is shown.
24-step ON/OFF time schedule settings
Embedded mounted type (mounting adapter Y92F-30 included)
Series H5F-A/-B
Surface mounted type
Series H5F-FA/-FB
Conventional size type
Series H5F-KA/-KB (vertical direction)
Series H5F-KAL (horizontal dimension)
Mounting Method | Embedded Mounting | Surface Mounting | Surface / DIN Rail Mounting (Conventional Type) |
---|---|---|---|
Vertical Direction | |||
Japanese Specification Format | Series H5F-A | Series H5F-FA | Series H5F-KA |
English Specification Format | Series H5F-B |
Model Configuration
Power Supply Voltage | 100 to 240 V AC, 50/60 Hz (Common) |
---|---|
Allowable Voltage Range | 85 to 110% of power supply voltage |
Power Consumption | Approx. 2.4 VA (At 264 V AC) |
Control Output | Contact 1a 250 V AC, 15 A (resistive load) 24 V DC, 10 A (resistive load) Minimum applied load 5 V DC, 100 mA (P level, reference value) |
Operating Temperature Range | −10 to +55°C (No Freezing) |
Storage Temperature Range | −25 to +65°C (No Freezing) |
Ambient Operating Humidity | 35 to 85% |
Case Exterior | Light Gray (Munsell 5Y7/1) |
Rating
Variations In Operating Time | (±0.01% ±0.05 s) or less*1 ±0.01% is the value for the set time interval. | |
---|---|---|
Set Error | ||
Voltage Effect | ||
Temperature Effect | ||
Electromagnetic Interference (According To EN61326-1) | ||
Time Accuracy | ±15 s/month (25°C) | |
Compensation Time For Power Outage | Continuous 5 years or more (25°C), 10 years or more (25°C, power failure ratio 50% or less)*2 (With lithium battery) | |
Insulation Resistance | 100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between discontinuous contacts) | |
Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) | |
Noise Resistance | Between power supply terminals: ±1.5 kV Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns) | |
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.375 mm, 3 directions, 4 cycles each (8 min/cycle) |
Malfunction | 10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each | |
Shock | Endurance | 300 m/s2, 3 axes each direction, 3 times each |
Malfunction | 100 m/s2, 3 axes each direction, 3 times each | |
Life | Mechanical | 100,000 operations or more (20°C) |
Electrical | 50,000 operations or more (resistive load, 250 V AC, 15 A) 50,000 operations or more (motor load, 250 V AC, 1 HP) 50,000 operations or more (inductive load, 250 V AC, 10 A, cosφ = 0.7) 50,000 operations or more (lamp load, 100 V AC, 100 W) 10,000 operations or more (lamp load, 100 V AC, 300 W) (+20°C) | |
Mass | Approx. 115 g (Series H5F-A), Approx. 160 g (Series H5F-KA), Approx. 130 g (Series H5F-FA) |
Performance
*1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are within (±0.01% ±0.05 s)
*2. Cumulative time of power failure
Safety Standards | cULus (listing): UL508/CSA C22.2 No. 14 EN61010-1 (IEC61010-1): Pollution Degree 2 / Overvoltage Category II A300 PILOT DUTY 1/3HP 120 VAC VDE0106/part10 Product Safety of Electrical Appliance and Material |
---|---|
EMC | (EMI) EN61326-1* Radiation interference field strength EN55011 Group 1 Class A Noise terminal voltage EN55011 Group 1 Class A (EMS) EN61326-1* Electrostatic discharge immunity EN61000-4-2: 4 kV direct, 8 kV atmospheric Field strength immunity EN61000-4-3: 10 V/mAM modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Conductive noise immunity EN61000-4-6: 10 V (0.15 to 80 MHz) Burst noise immunity EN61000-4-4: 2 kV power supply line, 1 kV output line Surge immunity EN61000-4-5: 1 kV between lines (power supply line, output line), 2 kV between grounds (power supply line, output line) Voltage dip / interruption immunity EN61000-4-11: 0.5 cycles, 100% (rated voltage) Magnetic field strength immunity EN61000-4-8: 30 A/m |
Applicable standards
*Industrial electromagnetic environment (EN/IEC61326-1 Table 2)
Global support
Conforms to the CE mark, all models conform to finger protection standards, so they can be securely used overseas.
Extensive applications
Supports 4 different mounting methods and 24-step ON/OFF operation for a variety of applications.
Usage example
Easily deal with sudden schedule changes using the "holiday function" and "semiautomatic operation."
Part Number |
---|
H5F-A |
H5F-B |
H5F-FA |
H5F-KA |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Mounting Method | Dimension vertical (mm) | Dimension width (mm) | Dimension depth (mm) |
---|---|---|---|---|---|---|---|---|---|
2,746,404 IDR 2,062,275 IDR | 1 Piece(s) | Same day | 10 | Panel | 48 | 48 | 63.7 | ||
3,422,971 IDR | 1 Piece(s) | Available | Same day | - | Panel | 48 | 48 | 63.7 | |
2,746,404 IDR 2,065,021 IDR | 1 Piece(s) | Same day | 10 | [Other] Surface mounting | 92 | 50 | 42.1 | ||
3,259,972 IDR 2,068,452 IDR | 1 Piece(s) | Same day | 10 | [Other] DIN rail/Surface mount | 101.2 | 50.5 | 60 |
Loading...
Type | Time switch | Display method | Liquid Crystal | Time specifications(s) | 24 h × 7 day (1-min units) |
---|---|---|---|---|---|
Power Supply Voltage | AC-dedicated | Rated power supply voltage(V) | AC 100–240 | Contact Configuration | 1a |
How can we improve?Bagaimana Kami bisa meningkatkan Pelayanan?
How can we improve?Bagaimana Kami bisa meningkatkan Pelayanan?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy Walaupun Kami tidak dapat langsung menjawab saran yang ditulis di lembar ini, informasinya akan kami review untuk peningkatan pelayanan dikemudian hari
Kebijakan Privacy
Thank you for your cooperation.Terima kasih atas kerjasama anda.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy Walaupun Kami tidak dapat langsung menjawab saran yang ditulis di lembar ini, informasinya akan kami review untuk peningkatan pelayanan dikemudian hari
Silahkan pergunakan Forms Permintaan.
Kebijakan Privacy