(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V (600V MLFC 0.75SQ-225)

Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V 600V MLFC 0.75SQ-225

[Features]
· Excellent heat resistance (110°C) and flame retardance.
· Excellent flexibility.
· Terminals are easily removable.

(i)Caution

  • · The finished outer diameter indicated in the filtering conditions is the max value. · Refer to the catalog for tolerances.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

600V MLFC 0.75SQ-225

Flame-Retardant Polyflex Cable MLFC Series 600 V / 1,500 V Structure

Flame-retardant Polyflex cable MLFC Series: Related Images

Flame-Retardant Polyflex Cable MLFC Series 600 V / 1,500 V Structural Drawing

Specifications and Dimensions of Flame-Retardant Polyflex Cable MLFC Series 600 V / 1,500 V

600 V

ConductorInsulator
Thickness
(mm)
Finishing outer diameter
(mm)
Conductor resistance
(20℃)
(Ω/km)
Test voltage
(V)
Insulation Resistance
(20℃)
(MΩ·km)
Surface leak resistance
(MΩ)
Reference
Nominal cross-sectional area
(mm^2)
Configuration
Number of strand / strand diameter
(strands/mm)
Outer diameter
(Approx.)
(mm)
Approximate weight
(kg/km)
Standard length of wire
(m)
32537/55/0.4527.02.930.8 to 33.20.0614350020503300300
25037/42/0.4523.62.928.0 to 29.60.0760300020502550300
20037/34/0.4521.22.925.1 to 26.90.0939300020602100300
15027/34/0.4518.72.321.7 to 22.70.129300020701500300
12519/42/0.4516.82.320.0 to 22.20.148300020701350300
10019/34/0.4515.22.318.5 to 20.30.183300030801100300
8019/27/0.4513.51.815.8 to 17.60.23025003090860300
6019/20/0.4511.61.814.0 to 15.60.311250030100650300
5019/16/0.4510.41.812.8 to 14.40.389250030100530300
387/34/0.459.11.411.0 to 12.40.496250040100410100
307/27/0.458.11.410.0 to 11.40.625220040100330100
227/20/0.457.01.48.9 to 10.30.844220040100260100
14 88/0.454.91.16.4 to 7.61.32220040200160200
8 50/0.453.71.15.2 to 6.42.32220050200100200
5.5 35/0.453.11.14.6 to 5.83.3122005030070400
3.5 45/0.322.51.14.0 to 5.25.3822005030050400
2.0 37/0.261.81.13.4 to 4.49.9122006030030400
1.25 50/0.181.51.13.1 to 4.115.522007030025400
0.75 30/0.181.11.12.8 to 3.725.822008030020400

1,500 V

ConductorInsulator
Thickness
(mm)
Finishing outer diameter
(mm)
Conductor resistance
(20℃)
(Ω/km)
Test voltage
(V)
Insulation Resistance
(20℃)
(MΩ·km)
Surface leak resistance
(MΩ)
Reference
Nominal cross-sectional area
(mm^2)
Configuration
Number of strand / strand diameter
(strands/mm)
Outer diameter
(Approx.)
(mm)
Approximate weight
(kg/km)
Standard length of wire
(m)
25037/42/0.4523.63.028.6 to 31.00.0760540020502600300
20037/34/0.4521.23.026.3 to 28.50.0939540020502150300
15027/34/0.4518.72.522.9 to 24.90.129540020601600300
12519/42/0.4516.82.521.1 to 23.10.148540020701400300
10019/34/0.4515.22.519.4 to 21.40.183540030701150300
8019/27/0.4513.52.517.8 to 19.60.23054003090920300
6019/20/0.4511.62.516.0 to 17.60.31154003090700300
5019/16/0.4510.42.514.8 to 16.40.389540040100580300
387/34/0.459.12.012.5 to 14.10.496540030100450100
307/27/0.458.12.011.6 to 13.00.625540040100370100
227/20/0.457.02.010.5 to 11.90.844540045100300100
1488/0.454.92.08.3 to 9.71.32540050100180200
850/0.453.72.07.2 to 8.42.32540060200120200
5.535/0.453.12.06.6 to 7.83.3154007020090200
3.545/0.322.52.06.0 to 7.25.3854008020070200
2.037/0.261.82.05.3 to 6.59.91540010020050400
1.2550/0.181.52.05.1 to 6.115.5540011020040400
Part Number
600V MLFC 0.75SQ-225
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Finished outer diameter
(mm)
Rated Voltage Representative Standard Other Properties

1,964,889 IDR

1 Piece(s) 8 Day(s) or more -2250.753.7600VPSEFlame retardant, flexibility, terminal removability

Loading...

  1. 1
 

Basic Information

Number Of Cores(Core) 1 Shield NA Properties Heat-Resistance / Cold Resistance
Insulation body materials Polyflex

Please check the type/dimensions/specifications of the part 600V MLFC 0.75SQ-225 in the Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V series.

Products like this...

Part Number
1500V MLFC 2SQ-11
1500V MLFC 2SQ-12
1500V MLFC 2SQ-13
600V MLFC 0.75SQ-226
600V MLFC 0.75SQ-227
600V MLFC 0.75SQ-228
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Finished outer diameter
(mm)
Rated Voltage Representative Standard Other Properties

303,882 IDR

1 Piece(s) 8 Day(s) or more -1126.5For High Voltages-Flame retardant, varnish resistant, flexibility

327,025 IDR

1 Piece(s) 8 Day(s) or more -1226.5For High Voltages-Flame retardant, varnish resistant, flexibility

351,584 IDR

1 Piece(s) 8 Day(s) or more -1326.5For High Voltages-Flame retardant, varnish resistant, flexibility

1,973,680 IDR

1 Piece(s) 8 Day(s) or more -2260.753.7600VPSEFlame retardant, flexibility, terminal removability

1,982,470 IDR

1 Piece(s) 8 Day(s) or more -2270.753.7600VPSEFlame retardant, flexibility, terminal removability

1,991,261 IDR

1 Piece(s) 8 Day(s) or more -2280.753.7600VPSEFlame retardant, flexibility, terminal removability

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)