Earth Leakage Circuit Breaker F Style NV-S Class (General-Purpose Product) Harmonic/Surge Compatible Type NV32-SVF

NV-S Type MITSUBISHI Earth Leakage Breakers Features

Standard support for mounting IEC 35 mm rail.
Standard compatibility with protection grade IP20 from all directions of terminal area.
Mountable operation handle for Earth Leakage Breakers.
Shunt trip device (SHT) can be mounted on the Earth Leakage Breakers.

NV-S Type MITSUBISHI Earth Leakage Breakers Specifications

Frame A3050100
Earth Leakage Breakers Type NameNV32-SVFNV63-SVFNV125-SVF
Rated Current in A (*3)
Standard Ambient Temperature 40°C
(5) (10)
15 20 30
(5) (10) 15
20 30 40 50
15 20 30 (40)
50 60 75 100
Number of Poles23233
Phase Wire Model (*1)1ø2 W3 ø3 W,
1 ø3 W,
1 ø2 W
1ø2 W3 ø3 W,
1 ø3 W,
1 ø2 W
3 ø3 W,
1 ø3 W,
1 ø2 W
Rated Operating Voltage Ue V (*2)AC100 to 240100 to 440100 to 240100 to 440100 to 440
High-Speed TypeRated Sensitivity Current mA3030 100
(200)
(500)
3030 100
(200)
(500)
30
100/200/500 switch
Maximum Operating Time sat I Δn0.10.10.1
at 5I Δn0.040.040.04
Time Delay TypeRated Sensitivity Current mA--(100/200/500 switch)
Maximum Operating Time s (*4)--(0.45/1.0/2.0 switch)
Minimum Limiting Non-actuating Time s--(0.1/0.5/1.0)
Rated Short Circuit
Breaking Capacity
kA
JIS C 8201-2-2 Ann. 1
JIS C 8201-2-2 Ann. 2
IEC 60947-2 2nd. ed.
(Icu/Ics)
(*5)
AC440 V-2.5/2.5-7.5/620/20
415 V-5/5-10/825/25
400 V-5/5-10/825/25
230 V7.5/7.515/1550/50
200 V7.5/7.515/1550/50
100 V7.5/7.515/1550/50
Rated Impulse Withstand Voltage Uimp (kV)46466
Isolation CompatibilityCompatibleCompatibleCompatible
Reverse Connection (Only When Using at 240 V AC or Less)--Available
External Dimensions
mm
a3654365475
b100100130
c686868
ca909090
Earth Leakage Breakers Connection MethodMost suitable for front-surface type crimp terminals
IEC 35 mm Rail-Mounting AdapterStandard EquipmentStandard EquipmentStandard Equipment
Electrical Appliances and Material Safety ActCompliantCompliantCompliant
Overcurrent Tripping MethodThermal-magneticThermal-magneticThermal-magnetic
Trip ButtonAvailableAvailableAvailable
Earth Leakage Breakers CE Mark---
CCC Certification---

*1: When using a 3-contact Earth Leakage Breakers for 1 ø2 W, do not use the center contact and connect the left and right contacts. When using for 1 ø3 W, connect the center contact to a neutral wire.
*2: Time delay type is 200 to 440 V for all models.
*3: The time delay type is fabricated at 20 A rated current or higher.
*4: Operation time for 0.45 s is 0.15 s to 0.45 s, for 1.0 s is 0.6 to 1.0 s, and for 2.0 s is 1.2 to 2.0 s.
*5: 2-contact product JIS C 8201-2-2 Ann. 1 Ann. 2 240 V AC breaking capacity is the same as 230 V AC.

External Dimensions of MITSUBISHI Earth Leakage Breakers

External dimensions

Variable Voltage Range in Which Electrical MITSUBISHI Earth Leakage Breakers Protection Function Can Operate

Earth Leakage Breakers Rated VoltageApplicable Circuit VoltageVariable Voltage Range in Which Electrical Leakage Protection Function Can Operate
100 to 240 V100, 110, 200, 220, 230, 240 V80 to 264 V
100 to 440 V100, 110, 200, 220, 240, 254, 265, 380, 400, 415, 440 V80 to 484 V
200 to 440 V200, 220, 240, 254, 265, 380, 400, 415, 440 V160 to 484 V
Part Number
NV32-SVF 2P 10A 30MA
NV32-SVF 2P 10A 100-240V 30MA
NV32-SVF 2P 20A 100-240V 30MA
NV32-SVF 2P 30A 100-240V 30MA
NV32-SVF 2P 32A 100-240V 30MA
NV32-SVF 3P 10A 30MA
NV32-SVF 3P 10A 100-440V 100MA
NV32-SVF 3P 20A 100-440V 30MA
NV32-SVF 3P 20A 100-440V 100MA
NV32-SVF 3P 30A 100-440V 100MA
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAmpere frame AF Rated block capacity AC 100 V
(kA)
Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Number of Poles Rated Operating Voltage
(V)
Rated Current
(A)
rate sensitivity current
(mA)
Mounting Method Representative Standard Dimension width
(mm)
Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method Type Specifications

1,795,830 IDR

1 Piece(s) Quote 30AF7.57.5-2AC100 to 4401030DIN/Screw retentionPSE36AvailableSurface formGeneral-Purpose ProductHigh Harmonics/Surge Compatible Table

1,795,830 IDR

1 Piece(s) Same day 30AF7.57.5-2AC100-2401030DIN/Screw retentionPSE / CE / TUV36AvailableSurface form--

1,633,833 IDR

1 Piece(s) Same day 30AF7.57.5-2AC100-2402030DIN/Screw retentionPSE / CE / TUV36AvailableSurface form--

1,795,830 IDR

1 Piece(s) Quote 30AF7.57.5-2AC100-2403030DIN/Screw retentionPSE / CE / TUV36AvailableSurface form--

1,795,830 IDR

1 Piece(s) Same day 32AF7.57.5-2AC 100–2403230DIN/Screw retentionPSE36AvailableSurface formGeneral-Purpose ProductHigh Harmonics/Surge Compatible Table

2,985,330 IDR

1 Piece(s) Quote 30AF7.57.5-3AC100 to 4401030DIN/Screw retentionPSE54AvailableSurface formGeneral-Purpose ProductHigh Harmonics/Surge Compatible Table

2,985,330 IDR

1 Piece(s) Quote 30AF7.57.553AC100-44010100DIN/Screw retentionPSE / CE / TUV54AvailableSurface form--

2,985,330 IDR

1 Piece(s) Quote 30AF7.57.553AC100-4402030DIN/Screw retentionPSE / CE / TUV54AvailableSurface form--

2,985,330 IDR

1 Piece(s) Quote 30AF7.57.553AC100-44020100DIN/Screw retentionPSE / CE / TUV54AvailableSurface form--

2,985,330 IDR

1 Piece(s) Quote 30AF7.57.553AC100-44030100DIN/Screw retentionPSE / CE / TUV54AvailableSurface form--

Loading...

  1. 1
 

Basic Information

Dimension height(mm) 100 Dimension depth(mm) 90

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)