NAP Series Single-Phase Noise Filter (General-Purpose / Single-Stage Filter / External Pulse Voltage Attenuation) (NAP-06-472)

NAP Series Single-Phase Noise Filter (General-Purpose / Single-Stage Filter / External Pulse Voltage Attenuation) NAP-06-472

Push-down terminal block external pulse voltage attenuation (NAP)

[Features]
· External impulse high attenuation type.
· Single phase 250V.
· Quick and easy push-down terminal block adoption (patent and design registration pending).
· With screw dropout prevention function

PDF

Part Number

Configured Part Number is shown.

NAP-06-472

INDEX

Features of NAP series

NAP series

NAP series

External impulse high attenuation type
Single-phase 250 V
It uses a quick and easy push-down terminal block (With screw fall prevention function)

Ordering information

Ordering information

1 Series name
2 Rated current
3 Ground capacitor code

  • * The attenuation characteristic differs depending on the ground capacitor code.

4 Option D: DIN rail mounting type

  • * The external shape differs when the option is set. Please refer to the drawing.

Ground capacitor code

CodeLeakage current
Input 125/250 V 60 Hz
Capacitor capacity
(Nominal value)
0005 µA / 10 µA maxN/A
47150 µA / 100 µA max470 pF
4720.5 mA / 1.0 mA max 4,700 pF

Product specifications

ItemNAP-04-472NAP-06-472NAP-10-472 NAP-16-472 NAP-20-472NAP-30-472
Rated Voltage〔V〕AC 1⌀ 250 / DC250
Rated current〔A〕4610162030
Test voltage (Between terminals and mounting plates)2,500 V AC (cutoff current = 20 mA), 1-minute, normal temperature normal humidity
Insulation resistance (Between terminals and mounting plates)500 V DC 100 MΩ min normal temperature normal humidity
Leakage current 125/250 V 60 Hz0.5 mA / 1.0 mA max
Voltage drop1.0 V max
Safety standard certified temperature- 25 to + 85°C (Refer to the derating characteristics)
Operating Temperature- 40 to + 85°C (Refer to the derating characteristics)
Operating Humidity20 to 95% RH (No condensation)
Storage temperature/humidity- 40 to + 85°C, 20 to 95% RH (No condensation)
Vibration10 to 55 Hz, 19.6 m/s^2 (2 G), period 3 minutes X, Y, Z direction 1 hour each
Impact196.1 m/s^2 (20 G) 11 ms X, Y, Z direction 1 time each
Safety StandardUL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil 3-1, ENEC (Except for DC input)
External dimensions (excluding protrusions) / weight53 × 41 × 92 mm (W × H × D) / 300 g max (Option: for -D, refer to the drawing)

Circuit Configuration

Circuit Configuration

Derating characteristics

Derating characteristics

Drawing

Since this product uses a push-down terminal block, it is shipped in the following conditions.
1 Terminal block cover is stored.
2 Terminal block screw is retained on the upper side.

Standard type

Standard type

DIN rail mounting type

DIN rail mounting type

  • * Tolerance: ±1
  • * Weight: 300 g max
  • * Mounting plate material: Steel (surface treatment: nickel plating) t = 1.0
  • * Case material: PBT
  • * Unit mm
  • * Terminal block tightening torque M4: 1.6 N⋅m (16.9 kgf⋅cm) max

Precautions for mounting DIN rail

Grounding through a DIN rail may not provide the proper noise attenuation effect.
Grounding should be done by connecting to the protective ground terminal (PE) of the noise filter main body.
There are 2 protective ground terminals, but you can use it even by connecting only one of them.

Precautions for mounting DIN rail

Characteristic data (Representative example)

NAP-06-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

Pulse attenuation characteristics pulse width 1 µs

Pulse attenuation characteristics pulse width 1 µs

NAP-10-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

Pulse attenuation characteristics pulse width 1 µs

Pulse attenuation characteristics pulse width 1 µs

NAP-16-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

Pulse attenuation characteristics pulse width 1 µs

Pulse attenuation characteristics pulse width 1 µs

NAP-20-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

Pulse attenuation characteristics pulse width 1 µs

Pulse attenuation characteristics pulse width 1 µs

NAP-30-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

Pulse attenuation characteristics pulse width 1 µs

Pulse attenuation characteristics pulse width 1 µs

Part Number
NAP-06-472
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSRated Current
(A)
Mounting Method H
(mm)
Leak current value
(mA max)

349,258 IDR

1 Piece(s) 8 Day(s) or more -6Fasten With Screws411(250V60Hz)

Loading...

  1. 1
 

Basic Information

Input Type Single-Phase Wiring Method Screw Fastening Safety standards UL / CUL / CSA
D(mm) 92 W(mm) 53 Representative standards (VDE) Corresponds To
Representative standards (ENEC) Corresponding (excluding time of DC input) External pulse voltage high attenuation Corresponds To

Please check the type/dimensions/specifications of the part NAP-06-472 in the NAP Series Single-Phase Noise Filter (General-Purpose / Single-Stage Filter / External Pulse Voltage Attenuation) series.

Products like this...

Part Number
NAP-04-472-D
NAP-16-000
NAP-16-472
NAP-20-471
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSRated Current
(A)
Mounting Method H
(mm)
Leak current value
(mA max)

399,730 IDR

1 Piece(s) 8 Day(s) or more 104DIN Rail481(250V60Hz)

411,178 IDR

1 Piece(s) 8 Day(s) or more -16Fasten With Screws410.01(250V60Hz)

411,178 IDR

1 Piece(s) 8 Day(s) or more -16Fasten With Screws411(250V60Hz)

429,237 IDR

1 Piece(s) 8 Day(s) or more -20Fasten With Screws410.1(250V60Hz)

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)