(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

2-Port Solenoid Valve for Dust Collector, VXF2 Series

2-Port Solenoid Valve for Dust Collector, VXF2 Series

It is a 2 port solenoid valve for dust collector VXF2 Series.
[Features]
・ Suitable for high temperature and large diameter
・ It can be mounted according to piping conditions (Flange Type)
・ It contributes to reduction of piping labor-hours, because there is no need to process orifice on the secondary (Flange body type)
・ Protective structure IP65 (Electrical entry flat terminal type terminal section is IP40)
· Improved armature durability
· UL94V-0 conforming flame resistance
・ Built-in full-wave rectifier type (AC specification)

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.
  • CAD data is not available for some model numbers.

PDF

Japanese Only

Product Specifications

2-Port Solenoid Valve for Dust Collector VXF2 Series product specifications 01

A: Straight pipe type

Product specifications 02 of 2-Port Solenoid Valve for Dust Collector VXF2 Series

B: Flange type

Product specifications 03 of 2-Port Solenoid Valve for Dust Collector VXF2 Series

C: Flange body type I
(Orifice body assembly type)

Product specifications 04 of 2-Port Solenoid Valve for Dust Collector VXF2 Series

D: Flange body type II
(Orifice body co-tightening type)

Product specifications 05 of 2-Port Solenoid Valve for Dust Collector VXF2 Series
Part Number
VXF22AAA
VXF22AAB
VXF22AAC
VXF22AAD
VXF22AAE
VXF22AAF
VXF22AAG
VXF22AAH
VXF22AAJ
VXF22AAK
VXF22AAL
VXF22AAM
VXF22AAN
VXF22AAP
VXF22AAQ
VXF22AAR
VXF22AAS
VXF22AAT
VXF22AAU
VXF22AAV
VXF22AAY
VXF22AAZ1B
VXF22AAZ1D
VXF22AAZ1E
VXF22AAZ1G
VXF22AAZ1L
VXF22AAZ1Q
VXF22AAZ2A
VXF22AAZ2B
VXF22AAZ2C
VXF22AAZ2D
VXF22AAZ2E
VXF22AAZ2G
VXF22AAZ2H
VXF22AAZ2J
VXF22AAZ2K
VXF22AAZ2L
VXF22AAZ2M
VXF22AAZ2N
VXF22AAZ2P
VXF22AAZ2R
VXF22AAZ3B
VXF22AAZ3C
VXF22AAZ3G
VXF22ABA
VXF22ABB
VXF22ABC
VXF22ABD
VXF22ABE
VXF22ABF
VXF22ABG
VXF22ABH
VXF22ABJ
VXF22ABK
VXF22ABL
VXF22ABM
VXF22ABN
VXF22ABP
VXF22ABQ
VXF22ABR
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Type Plumbing Thread Nominal Tube Flange Nominal Orifice Dia.
(Ø)
Operating Temperature Range
(°C)
Voltage Option Body material Lead wire electrical entry Piping Specifications Piping Connection Port Diameter Pipe connection thread of piping options

1,322,487 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMGrommetStraight pipe typeStandard25 ANone

1,322,487 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,322,487 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,322,487 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,322,487 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,622,340 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,472,094 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,472,094 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,472,094 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,472,094 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,472,094 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,663,560 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,497,204 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,497,204 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,663,560 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,384,776 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,384,776 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,384,776 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,384,776 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWithout silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMFastonStraight pipe typeStandard25 ANone

1,469,430 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeSpecial voltage25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~6012 V DCWithout silencerPOMGrommetStraight pipe typeSpecial voltage25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~6012 V DCWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeSpecial voltage25 ANone

1,472,094 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage25 ANone

1,497,204 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage25 ANone

1,384,776 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMConduit (With surge voltage suppressor)Straight pipe typeSpecial voltage25 ANone

1,596,672 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

1,596,672 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60240 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~6012 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60-Without silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

1,732,770 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

1,559,493 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWithout DIN connector25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWithout DIN connector25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60220 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWithout DIN connector25 ANone

1,414,908 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-With silencerPOMGrommetStraight pipe typeStandard25 ANone

1,414,908 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,414,908 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,414,908 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,572,120 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,552,446 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-With silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,564,515 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-With silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,564,515 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,564,515 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,738,350 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,589,625 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60-With silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,589,625 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60100 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,589,625 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60110 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

1,589,625 IDR

1 Piece(s) 31 Day(s) [Rc (R)] Rc (R)1---10~60200 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

-

1 Piece(s) 15 Day(s) [Rc (R)] Rc (R)1---10~60230 V DCWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard25 ANone

Loading...

Basic Information

Type Electromagnetic Type Applicable Fluid Air Operating Environment Standard
Switching Type Normally Closed Driving Type Pilot Type

Tech Support