(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Pilot Operated 2 Port Solenoid Valve VXP21/22/23 Series (Part Numbers)

Pilot Operated 2 Port Solenoid Valve VXP21/22/23 Series

[Features]
・ An abundant variety of combinations. A wide range of fluids can be controlled
・ Disassembly and assembly can be done in a short time
・ Selection of threaded or flange mounting is possible.

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images only. Please refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
VXP2380F-40-4G
VXP2380F-40-5DZ
VXP2380F-40-5G
VXP2380F-40-5GS
VXP2380F-40-5T
VXP2380S-40-1C
VXP2380S-40-1G
VXP2380S-40-1T
VXP2380S-40-1TL
VXP2380S-40-1TS
VXP2380S-40-1TZ
VXP2380S-40-2C
VXP2380S-40-2G
VXP2380S-40-2T
VXP2380S-40-2TL
VXP2380S-40-2TS
VXP2380S-40-2TZ
VXP2380S-40-3C
VXP2380S-40-3G
VXP2380S-40-3TZ
VXP2380S-40-4C
VXP2380S-40-4G
VXP2380S-40-4T
VXP2380S-40-4TL
VXP2380S-40-4TS
VXP2380S-40-4TZ
VXP2382-40-1C
VXP2382-40-1D
VXP2382-40-1DS
VXP2382-40-1DZ
VXP2382-40-1G
VXP2382-40-1GS
VXP2382-40-1T
VXP2382-40-1TL
VXP2382-40-1TS
VXP2382-40-1TZ
VXP2382-40-2C
VXP2382-40-2D
VXP2382-40-2DS
VXP2382-40-2DZ
VXP2382-40-2G
VXP2382-40-2GS
VXP2382-40-2T
VXP2382-40-2TL
VXP2382-40-2TS
VXP2382-40-2TZ
VXP2382-40-3C
VXP2382-40-3D
VXP2382-40-3DL
VXP2382-40-3DS
VXP2382-40-3DZ
VXP2382-40-3G
VXP2382-40-3GS
VXP2382-40-3T
VXP2382-40-3TL
VXP2382-40-3TS
VXP2382-40-3TZ
VXP2382-40-4C
VXP2382-40-4D
VXP2382-40-4DS
VXP2382-40-4GS
VXP2382-40-4T
VXP2382-40-4TL
VXP2382-40-4TS
VXP2382-40-4TZ
VXP2382-40-5C
VXP2382-40-5D
VXP2382-40-5DS
VXP2382-40-5DZ
VXP2382-40-5G
VXP2382-40-5GS
VXP2382-40-5T
VXP2382-40-5TL
VXP2382-40-5TS
VXP2382-40-5TZ
VXP2382A-40-2DL
VXP2382A-40-4TL
VXP2382A-40-5DZ
VXP2382A-40-5TL
VXP2382B-40-3T
VXP2382C-40-3C
VXP2382D-40-2TL
VXP2382D-40-4G
VXP2382D-40-4TZ
VXP2382E-40-1G
VXP2382E-40-2TL
VXP2382F-40-2TL
VXP2382F-40-5DZ
VXP2382F-40-5G
VXP2382S-40-1C
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Operating Environment Switching Type Connection Type Plumbing Thread Nominal Tube Flange Nominal Insulation Class Voltage Sealing materials Option Body material Bracket Valve type Lead wire electrical entry Body size Body type Compatible models Terminal box

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally ClosedTube Flange-40B220 V AC 50/60 HzFKMNoneC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally ClosedTube Flange-40B-FKMSurge voltage suppressor / With lightC37 or CAC408NoneOpen when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally ClosedTube Flange-40B-FKMNoneC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally ClosedTube Flange-40B-FKMWith surge suppressorC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally ClosedTube Flange-40B-FKMNoneC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H100 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H100 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H100 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H100 V AC 50/60 HzPTFE (FKM)With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H100 V AC 50/60 HzPTFE (FKM)With surge suppressorC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H100 V AC 50/60 HzPTFE (FKM)Surge voltage suppressor / With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H200 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H200 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H200 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H200 V AC 50/60 HzPTFE (FKM)With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H200 V AC 50/60 HzPTFE (FKM)With surge suppressorC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

7,162,668 IDR

1 Piece(s) 31 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H200 V AC 50/60 HzPTFE (FKM)Surge voltage suppressor / With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

6,928,740 IDR

1 Piece(s) 31 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H110 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H110 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H110 V AC 50/60 HzPTFE (FKM)Surge voltage suppressor / With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

7,573,500 IDR

1 Piece(s) 31 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H220 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit40AVXP23--

6,863,454 IDR

1 Piece(s) 20 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H220 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedGrommet40AVXP23--

7,046,190 IDR

1 Piece(s) 20 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H220 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H220 V AC 50/60 HzPTFE (FKM)With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H220 V AC 50/60 HzPTFE (FKM)With surge suppressorC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally ClosedTube Flange-40H220 V AC 50/60 HzPTFE (FKM)Surge voltage suppressor / With lightC37 or CAC408NoneOpen when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B100 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRWith lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

7,582,500 IDR

1 Piece(s) 20 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRNoneC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRWith surge suppressorC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzNBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRNoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRNoneC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRWith surge suppressorC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRWith surge suppressorC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRNoneC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRWith surge suppressorC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-NBRSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B200 V AC 50/60 HzFKMWith lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B220 V AC 50/60 HzFKMWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

8,363,520 IDR

1 Piece(s) 31 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-FKMSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B-FKMWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzEPDMNoneC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

7,762,149 IDR

1 Piece(s) 31 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40B110 V AC 50/60 HzPTFENoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40H200 V AC 50/60 HzFKMWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40H220 V AC 50/60 HzFKMNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40H220 V AC 50/60 HzFKMSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40H100 V AC 50/60 HzEPDMNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40H200 V AC 50/60 HzEPDMWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally OpenTube Flange-40B200 V AC 50/60 HzFKMWith lightC37 or CAC408NoneClosed when energizedConduit terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally OpenTube Flange-40B-FKMSurge voltage suppressor / With lightC37 or CAC408NoneClosed when energizedDIN terminal40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandard / No oilNormally OpenTube Flange-40B-FKMNoneC37 or CAC408NoneClosed when energizedGrommet40AVXP23--

-

1 Piece(s) 15 Day(s) Electromagnetic TypeStandardNormally OpenTube Flange-40H100 V AC 50/60 HzPTFE (FKM)NoneC37 or CAC408NoneClosed when energizedConduit40AVXP23--

Loading...

Basic Information

Applicable Fluid Air / Water / Oil / Gas / Steam Driving Type Pilot Type

Tech Support