Impulse Lubricator ALIP1000/1100 Series (ALIM1000-5)

Impulse Lubricator ALIP1000/1100 Series ALIM1000-5

[Features]
· Intermittent discharge of small yet constant amounts to the sliding parts.
· Directly supplies a constant amount of oil just before the lubrication point.

(i)Caution

  • Refer to the catalog for details on product specifications.
  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Part Number

Configured Part Number is shown.

ALIM1000-5

ALIP1000/1100 Series Impulse Lubricator Specifications

ALIP1000-01 JIS symbol

ALIP1000-01 JIS symbol

ALIP1100-01 JIS symbol

ALIP1100-01 JIS symbol

ModelALIP1000-01ALIP1100-01
Port size Rc (nominal size)1/8 (6A)
Proof pressure1.0 MPa
Operating pressure range for signal pressure0.25 to 0.7 MPa
Pressure range for oilNote 1)0 to 0.4 MPa0.15 to 0.4 MPa
Oil viscosityNote 1)2 to 460 cst (40°C)
Ambient temperature and working fluid temperature5 to 50°C
Oil feeding volume (1 shot)Note 2)0 to 0.04 cm3
Weight (kg)0.22
Mounting orientationOIL OUT upwardNo restriction

Note 1) Determine the oil pressure and port size based on the piping length and oil viscosity, referring to the operation manual.
Note 2) The oil feeding volume adjustment range is 0.003 to 0.04 cm3. The set oil feeding volume at the time of shipment is 0.02 cm3.

Outline dimensional drawing

 

(Unit: mm)

 

Impulse lubricator: ALIP1□00-01 dimensional drawing

Impulse lubricator: ALIP1□00-01 dimensional drawing

 

(Unit: mm)

 

Impulse lubricator manifold: ALIM1□00-2, -4, -6, -8, -10 dimensional drawing

Impulse lubricator manifold: ALIM1□00-2, -4, -6, -8, -10 dimensional drawing

 

(Unit: mm)

 

Impulse lubricator manifold: ALIM1□00-3, -5, -7, -9 dimensional drawing

Impulse lubricator manifold: ALIM1□00-3, -5, -7, -9 dimensional drawing

 

(Unit: mm)

 

Part numberImpulse lubricator modelNo. of stationsLL1
ALIM1000-2ALIP1000-0126860
ALIM1100-2ALIP1100-01
ALIM1000-4ALIP1000-014116108
ALIM1100-4ALIP1100-01
ALIM1000-6ALIP1000-016164156
ALIM1100-6ALIP1100-01
ALIM1000-8ALIP1000-018212204
ALIM1100-8ALIP1100-01
ALIM1000-10ALIP1000-0110260252
ALIM1100-10ALIP1100-01
ALIM1000-3ALIP1000-013116108
ALIM1100-3ALIP1100-01
ALIM1000-5ALIP1000-015164156
ALIM1100-5ALIP1100-01
ALIM1000-7ALIP1000-017212204
ALIM1100-7ALIP1100-01
ALIM1000-9ALIP1000-019260252
ALIM1100-9ALIP1100-01

*The specifications are the same as the impulse lubricator specifications.

Piping Example

Intermittent Lubrication and Constant Amount of Oil Dropping to the Friction Part of Machines, Such as Gears

No pressurized tank example

No pressurized tank example

Pressurized tank example

Pressurized tank example

Lubrication to Pneumatic Equipment Such as Air Cylinders

No pressurized tank example

No pressurized tank example

Pressurized tank example

Pressurized tank example

Operating Principle

ALIP1000/1100 Series Working Principle

ALIP1000/1100 Series Working Principle

In the figure above, when pilot air enters the inlet side of piston (1), piston (1) overcomes piston spring (2) and pushes oil into the pump chamber. At this time steel ball (5) is pushed downward and closes the oil entry passage.
The volume of oil in the pump chamber, equivalent to (the cross sectional area of the pump chamber intrusion piston) × (the piston stroke), pushes open check valve (3) and is discharged from the outlet side.
After the oil discharge finishes, check valve (3) closes the outlet side passage using check valve spring (4).
After the pilot air is released, piston (1) recovers by using piston spring (2), steel ball (5) is pulled upward, and new oil flows into the pump chamber from the oil entry passage.
Rotate handle (6) and change the stroke of piston (1) to adjust the volume of oil discharged. Turning the handle left will increase the discharge volume, while turning to the right will decrease it. The movement of the piston can be confirmed visually by using indicator (7).

Precautions

Adjustment

  • *1 At the time of shipment, the impulse lubricator is set to an oil discharge volume of 0.02 cm3, but when necessary, this can be adjusted by pulling the handle to release the lock, then rotating the handle.
  • *2Rotating the handle to the right will reduce the volume of discharge, while rotating it to the left will increase it. One revolution of the handle will change the discharge volume by only about 0.007 cm3. After adjustment, push the handle back in to lock it.

Lubrication

  • *1After supplying oil to the oil tank, a large volume of air bubbles will be mixed in with the oil, so either wait for the air bubbles to dissipate, or use vacuum suction to remove the bubbles before using the equipment.
  • *2If air enters the interior of the impulse lubricator pump chamber, oil will cease to be discharged; if this happens, be sure to release the air.
  • *3Never screw any plug, etc. into the OIL OUT side of the impulse lubricator.

Other precautions

*See the manufacturer's catalog for product information other than the above.

Part Number
ALIM1000-5
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Number of stations Applicable impulse lubricator model Oil supply pressure

10,777,745 IDR

1 Piece(s) 20 Day(s) Impulse lubricator manifold5 stationsALIP1000-01None

Loading...

  1. 1

Basic Information

Type Lubricating Device

Please check the type/dimensions/specifications of the part ALIM1000-5 in the Impulse Lubricator ALIP1000/1100 Series series.

Products like this...

Part Number
ALIM1000-2
ALIM1000-3
ALIM1000-4
ALIM1100-10
ALIM1100-2
ALIM1100-8
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Number of stations Applicable impulse lubricator model Oil supply pressure

5,112,835 IDR

1 Piece(s) 31 Day(s) Impulse lubricator manifoldDoubleALIP1000-01None

7,001,110 IDR

1 Piece(s) 31 Day(s) Impulse lubricator manifoldTripleALIP1000-01None

8,889,470 IDR

1 Piece(s) 31 Day(s) Impulse lubricator manifold4 stationsALIP1000-01None

20,219,290 IDR

1 Piece(s) 20 Day(s) Impulse lubricator manifold10 stationsALIP1100-01None

5,112,835 IDR

1 Piece(s) 31 Day(s) Impulse lubricator manifoldDoubleALIP1100-01None

16,442,655 IDR

1 Piece(s) 20 Day(s) Impulse lubricator manifold8 stationsALIP1100-01None

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)