(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Large Size 5-Port Solenoid Valve, VP4□50/4□70 Series Elastic Body Seal (Part Numbers)

Large Size 5-Port Solenoid Valve, VP4□50/4□70 Series Elastic Body Seal

- Large Size 5-Port Solenoid Valve, VP4□50/4□70 Series Elastic Body Seal from SMC.
- Solenoid valve for driving large cylinders.
- Manifold model: VVP45, VVP46
- This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
- Operating pressure range is 0.2 to 0.9 MPa.
- Operating ambient and fluid temperature is 0 to 60 °C (No freezing).
- Pipe port type can be selected 4 types, Rc, NPT, NPTF or G.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Large Size, 5-Port Solenoid Valve, VP4□50/4□70 Series, Rubber Seal Specifications

VP4□50/4□70 Series external appearance

VP4□50/4□70 Series external appearance

Usable FluidsAir
Operating Pressure Range MPa0.2 to 0.9
Ambient Temperature and Operating Fluid Temperature °C0 to 60 (no freezing)
Maximum Operating Frequency Hz3
*1: LubricationRequired (Type 1 turbine oil, ISO VG32 equivalent)
Manual OperationYes (non-locking)
Mounting OrientationFree
*2: Impact Resistance / Vibration Resistance: m/s2150/50
Standard accessoriesSilencer for pilot EXH (AN101-01)

*1: The solenoid valve is a lubrication type. Use an equivalent class 1 turbine oil (ISO VG32).
*2: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunction occurred in 1 sweep test between 45 and 1,000 Hz. The test was performed in both energized and de-energized states in the axial and right angle directions of the main valve/armature. (Initial value)

Solenoid Specifications

Electrical EntryStandardGrommet (G)
Conduit terminal (T)
DIN terminal (D)
Semi-standardConduit terminal with indicator light (TL)
DIN terminal with indicator light (DL)
Coil rated voltage (V)AC (50/60 Hz)100, 200, 110, 220, 240
DC12, 24
Allowable Voltage Fluctuation-15% to +10% of rated voltage
*Apparent power (VA)ACStarting73 (50 Hz), 58 (60 Hz)
Holding28 (50 Hz), 17 (60 Hz)
*Power consumption (W)DC12

*At rated voltage

Response time*

ModelVP4150VP4170VP4250VP4270VP4350VP4450
Response Time ms (at 0.5 MPa)ACON30 or less40 or less30 or less30 or less30 or less30 or less
OFF50 or less65 or less30 or less30 or less30 or less30 or less
DCON40 or less55 or less40 or less45 or less40 or less40 or less
OFF40 or less55 or less40 or less45 or less30 or less30 or less

*Based on JIS B8419:2010 dynamic performance testing (Coil temperature 20°C, at rated voltage, without surge voltage suppressor)

Structure Drawing

2-position single structure drawing / connection drawing

2-position single structure drawing / connection drawing

2-position double structure drawing / connection drawing

2-position double structure drawing / connection drawing

3-position closed center / exhaust center structure drawing / connection drawing

3-position closed center / exhaust center structure drawing / connection drawing

NumberPart nameMaterialNote
1BodyAluminum alloyPlatinum silver
2PlateAluminum alloyPlatinum silver
3CapAluminum alloyPlatinum silver
4SpacerAluminum alloyPlatinum silver
5SpoolStainless steel, aluminum alloy-
6Sleeve2-position: Aluminum alloy
3-position: Brass
-
7Piston2-position: Resin
3-position: Stainless steel
-
8Center sleeveResin-
9Side poppetBrass, NBR-
NumberPart nameNote
10Sub-plate3/8VP4□50Aluminum alloy
Part numbers* are the same symbol as the notation method for the thread type.
1/2
3/4
1
1 1/4VP4□70
1 1/2
11GasketVP4□50-
VP4□70
Hexagon Socket Head BoltVP4□50Valve mounting screw. Model for VP4□70 requires a separate spring washer.
VP4□70
12Pilot Valve AssemblySee the manufacturer's catalog (p. 353) for the pilot valve model number notation.

Drawings / VP4150

 

(Unit: mm)

 

Grommet: VP4150-□□G-□ dimensional drawings

Grommet: VP4150-□□G-□ dimensional drawings

*Dimensions within parentheses are for port sizes 3/4 and 1

 

(Unit: mm)

 

Conduit terminal: VP4150-□□T-□ dimensional drawing

Conduit terminal: VP4150-□□T-□ dimensional drawing

*Dimensions within parentheses are for port sizes 3/4 and 1

 

(Unit: mm)

 

DIN terminal: VP4150-□□D-□ dimensional drawing

DIN terminal: VP4150-□□D-□ dimensional drawing

*Dimensions within parentheses are for port sizes 3/4 and 1

Drawings / VP4250/VP4350/VP4450

 

(Unit: mm)

 

Grommet: VP4250-□□G-□/VP4350-□□G-□/VP4450-□□G-□ dimensional drawings

Grommet: VP4250-□□G-□/VP4350-□□G-□/VP4450-□□G-□ dimensional drawings

*Dimensions within parentheses are for port sizes 3/4 and 1

 

(Unit: mm)

 

Conduit terminal: VP4250-□□T-□/VP4350-□□T-□/VP4450-□□T-□ dimensional drawing

Conduit terminal: VP4250-□□T-□/VP4350-□□T-□/VP4450-□□T-□ dimensional drawing

*Dimensions within parentheses are for port sizes 3/4 and 1

 

(Unit: mm)

 

DIN terminal: VP4250-□□D-□/VP4350-□□D-□/VP4450-□□D-□ dimensional drawing

DIN terminal: VP4250-□□D-□/VP4350-□□D-□/VP4450-□□D-□ dimensional drawing

*Dimensions within parentheses are for port sizes 3/4 and 1

Precautions

  1. *1Piping: Pipe the P port so that supply air pressure remains above the operating pressure while operating. If throttling the air flow of the P port or opening the A/B ports in the atmosphere (or opening in almost the same conditions), pressure drops during valve operation can result in valve malfunctions.
  2. *2Air quality: Install an air filter and a lubricator on the upstream side.
  3. *3Lubrication: This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32). Contact the manufacturer support center regarding brands from each company.
  4. *4Operating environment: In dusty environments, install a silencer to EA/EB/Pilot EXH ports, etc., to prevent dust from entering.
  5. *5Operation in low temperatures: If operating in low temperatures, the external pilot type solenoid valve is recommended. 6 VP435□ (3-position closed center type): Be aware that this valve is constructed so that pressure in the cylinder will be discharged via the P port (causing the cylinder to move) if supply pressure to the P port is discharged or decreased when the cylinder is in an intermediate stop state.
  6. *6How to calculate flow rate: See the manufacturer's catalog for how to calculate flow rate.
  7. *7See the manufacturer's catalog for information other than that above.
Part Number
VP4270-121T
VP4270-121TL
VP4270-122D
VP4270-122DL
VP4270-122G
VP4270-122T
VP4270-122TL
VP4270-123D
VP4270-123DL
VP4270-123DL-N
VP4270-123G
VP4270-123T
VP4270-123TL
VP4270-124D
VP4270-124D-F
VP4270-124DL
VP4270-124G
VP4270-124T
VP4270-124TL
VP4270-125D
VP4270-125D-F
VP4270-125DL
VP4270-125DL-N
VP4270-125G
VP4270-125G-F
VP4270-125T
VP4270-125T-F
VP4270-125TL
VP4270-126T
VP4270-127D-F
VP4270-141D
VP4270-141DL
VP4270-141G
VP4270-141T
VP4270-141TL
VP4270-142D
VP4270-142DL
VP4270-142G
VP4270-142T
VP4270-142TL
VP4270-143D
VP4270-143DL
VP4270-143G
VP4270-143T
VP4270-143TL
VP4270-144D
VP4270-144D-F
VP4270-144DL
VP4270-144G
VP4270-144T
VP4270-144TL
VP4270-145D
VP4270-145D-F
VP4270-145D-N
VP4270-145DL
VP4270-145DL-F
VP4270-145DL-N
VP4270-145DL-T
VP4270-145G
VP4270-145TL
VP4270-147D-F
VP4270-147T
VP4274-001D
VP4274-001DL
VP4274-001G
VP4274-001T
VP4274-001TL
VP4274-002D
VP4274-002DL
VP4274-002G
VP4274-002T
VP4274-002TL
VP4274-003D
VP4274-003DL
VP4274-003G
VP4274-003T
VP4274-003TL
VP4274-004D
VP4274-004DL
VP4274-004G
VP4274-004T
VP4274-004TL
VP4274-005D
VP4274-005DL
VP4274-005G
VP4274-005T
VP4274-005TL
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplication Mounting Orientation Number of Solenoids Switching Type Status at Power Off Voltage Pipe Port Type Plumbing Thread Nominal CV Value Lead wire electrical entry Piping specifications Body size

14,654,682 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/4-Conduit terminalSide ported1 1/4 standard

16,591,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/4-Conduit terminal with indicator lightSide ported1 1/4 standard

16,116,480 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/4-DIN terminalSide ported1 1/4 standard

16,424,370 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/4-DIN terminal with indicator lightSide ported1 1/4 standard

14,274,144 IDR

1 Piece(s) 31 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/4-GrommetSide ported1 1/4 standard

16,283,250 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/4-Conduit terminalSide ported1 1/4 standard

16,591,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/4-Conduit terminal with indicator lightSide ported1 1/4 standard

16,116,480 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/4-DIN terminalSide ported1 1/4 standard

16,424,370 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/4-DIN terminal with indicator lightSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110VNPT1 1/4-DIN terminal with indicator lightSide ported1 1/4 standard

14,274,144 IDR

1 Piece(s) 31 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/4-GrommetSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/4-Conduit terminalSide ported1 1/4 standard

16,038,000 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/4-Conduit terminal with indicator lightSide ported1 1/4 standard

16,116,480 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/4-DIN terminalSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220VG1 1/4-DIN terminalSide ported1 1/4 standard

16,424,730 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/4-DIN terminal with indicator lightSide ported1 1/4 standard

15,860,160 IDR

1 Piece(s) 31 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/4-GrommetSide ported1 1/4 standard

14,654,682 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/4-Conduit terminalSide ported1 1/4 standard

14,931,864 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/4-Conduit terminal with indicator lightSide ported1 1/4 standard

16,314,210 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/4-DIN terminalSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VG1 1/4-DIN terminalSide ported1 1/4 standard

14,959,971 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/4-DIN terminal with indicator lightSide ported1 1/4 standard

16,622,010 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VNPT1 1/4-DIN terminal with indicator lightSide ported1 1/4 standard

14,523,300 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/4-GrommetSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VG1 1/4-GrommetSide ported1 1/4 standard

16,480,890 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/4-Conduit terminalSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VG1 1/4-Conduit terminalSide ported1 1/4 standard

16,788,780 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/4-Conduit terminal with indicator lightSide ported1 1/4 standard

16,480,890 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC12V[Rc (R)] Rc1 1/4-Conduit terminalSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC240VG1 1/4-DIN terminalSide ported1 1/4 standard

16,116,480 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/2-DIN terminalSide ported1 1/4 standard

16,424,370 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

15,859,800 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/2-GrommetSide ported1 1/4 standard

16,283,250 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/2-Conduit terminalSide ported1 1/4 standard

16,591,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V[Rc (R)] Rc1 1/2-Conduit terminal with indicator lightSide ported1 1/4 standard

16,116,480 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/2-DIN terminalSide ported1 1/4 standard

16,424,370 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

15,859,800 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/2-GrommetSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/2-Conduit terminalSide ported1 1/4 standard

16,591,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V[Rc (R)] Rc1 1/2-Conduit terminal with indicator lightSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/2-DIN terminalSide ported1 1/4 standard

16,424,370 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

15,859,800 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/2-GrommetSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/2-Conduit terminalSide ported1 1/4 standard

14,931,864 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V[Rc (R)] Rc1 1/2-Conduit terminal with indicator lightSide ported1 1/4 standard

14,505,075 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/2-DIN terminalSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220VG1 1/2-DIN terminalSide ported1 1/4 standard

16,424,370 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

15,325,200 IDR

1 Piece(s) 31 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/2-GrommetSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/2-Conduit terminalSide ported1 1/4 standard

16,591,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V[Rc (R)] Rc1 1/2-Conduit terminal with indicator lightSide ported1 1/4 standard

14,682,789 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/2-DIN terminalSide ported1 1/4 standard

15,143,760 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VG1 1/2-DIN terminalSide ported1 1/4 standard

16,314,030 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VNPT1 1/2-DIN terminalSide ported1 1/4 standard

16,622,010 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

16,622,190 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VG1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

16,622,010 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VNPT1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24VNPTF1 1/2-DIN terminal with indicator lightSide ported1 1/4 standard

14,451,858 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/2-GrommetSide ported1 1/4 standard

16,788,780 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V[Rc (R)] Rc1 1/2-Conduit terminal with indicator lightSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC240VG1 1/2-DIN terminalSide ported1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC240V[Rc (R)] Rc1 1/2-Conduit terminalSide ported1 1/4 standard

10,497,519 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V---DIN terminalWithout sub-plate1 1/4 standard

11,971,890 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V---DIN terminal with indicator lightWithout sub-plate1 1/4 standard

11,407,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V---GrommetWithout sub-plate1 1/4 standard

11,830,680 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V---Conduit terminalWithout sub-plate1 1/4 standard

12,138,660 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC100V---Conduit terminal with indicator lightWithout sub-plate1 1/4 standard

11,663,910 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V---DIN terminalWithout sub-plate1 1/4 standard

11,971,890 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V---DIN terminal with indicator lightWithout sub-plate1 1/4 standard

11,407,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V---GrommetWithout sub-plate1 1/4 standard

11,830,680 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V---Conduit terminalWithout sub-plate1 1/4 standard

12,138,660 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC200V---Conduit terminal with indicator lightWithout sub-plate1 1/4 standard

11,663,910 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V---DIN terminalWithout sub-plate1 1/4 standard

11,971,890 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V---DIN terminal with indicator lightWithout sub-plate1 1/4 standard

11,407,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V---GrommetWithout sub-plate1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V---Conduit terminalWithout sub-plate1 1/4 standard

12,138,660 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC110V---Conduit terminal with indicator lightWithout sub-plate1 1/4 standard

-

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V---DIN terminalWithout sub-plate1 1/4 standard

11,971,890 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V---DIN terminal with indicator lightWithout sub-plate1 1/4 standard

11,407,230 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V---GrommetWithout sub-plate1 1/4 standard

10,648,098 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V---Conduit terminalWithout sub-plate1 1/4 standard

12,138,660 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingAC220V---Conduit terminal with indicator lightWithout sub-plate1 1/4 standard

10,675,233 IDR

1 Piece(s) 20 Day(s) Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V---DIN terminalWithout sub-plate1 1/4 standard

12,169,440 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V---DIN terminal with indicator lightWithout sub-plate1 1/4 standard

11,604,870 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V---GrommetWithout sub-plate1 1/4 standard

12,028,320 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V---Conduit terminalWithout sub-plate1 1/4 standard

12,336,300 IDR

1 Piece(s) Quote Unit for Manifold MountingManifold BaseDouble2-Position Normally OpenSelf-RetainingDC24V---Conduit terminal with indicator lightWithout sub-plate1 1/4 standard

Loading...

Basic Information

Type Solenoid Valves Number of Ports 5-Port Valve Specifications Standard
Plumbing Sub-Base Plumbing Driving Type Pilot Type Spool Seal Type Soft Seal
Pressure Rating(MPa) 02 to 0.9 Pilot Air Supply Internal Manual Switch Non-Locking

Tech Support