(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Air Catch Sensor ISA2 Series For Double Notation And Additional Stations

Air Catch Sensor ISA2 Series For Double Notation And Additional Stations

This air catch sensor enables construction of a unit with a regulator and 2-port valve.
[Features]
· For double notation and additional stations.
· Clearance detection.
· With LED level meter.
· Connection with connectors.
· Easy to increase and decrease the number of manifold stations.

(i)Caution

  • Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Air Catch Sensor ISA2 Series Specifications

Air Catch Sensor ISA2 Series external appearance (individual wiring)

Air Catch Sensor ISA2 Series external appearance (individual wiring)

Air Catch Sensor ISA2 Series external appearance (centralized wiring)

Air Catch Sensor ISA2 Series external appearance (centralized wiring)

Specifications

ModelISA2-G□□□1□ISA2-G□□□5□ISA2-H□□□1□ISA2-H□□□5□
Detection distance0.01 to 0.25 mm0.03 to 0.50 mm
Applicable fluidDry air (filtered to 5 μm)
Operating pressure range30 to 200 kPa50 to 200 kPa
Recommended detection nozzleø1.5 (diameter 1.5 mm)ø2.0 (diameter 2.0 mm)
Consumption flow rate
L/min (ANR)
Supply pressure50 kPa5 or less10 or less
100 kPa8 or less15 or less
200 kPa12 or less22 or less
Power supply voltage12 to 24 V DC ±10%, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption15 mA or less
Switch output-NPN open
collector: 1 output
PNP open
collector: 1 output
NPN open
collector: 1 output
PNP open
collector: 1 output
Maximum load current80 mA
Maximum applied voltage30 V (at NPN output)
Residual voltage1.5 V or less (at 80 mA)
Short-circuit protectionYes
Repeatability (including temperature characteristics)0.01 mm or less (detection distance range 0.01 to 0.15 mm, supply pressure 100 to 200 kPa)0.01 mm or less (detection distance range 0.03 to 0.15 mm, supply pressure 100 to 200 kPa)
Hysteresis*10.01 mm or less (detection distance range 0.01 to 0.15 mm)0.01 mm or less (detection distance range 0.03 to 0.15 mm)
Indicator lightLED level meter*2 with 1 red, 2 green
(Set value < detection distance: red, Set value = detection distance: green 1, Set value > detection distance: green 1 + green 2)
EnvironmentEnclosureIP66: without pressure gauge, IP40: with pressure gauge
Operating temperature rangeOperating: 0 to 60°C, Stored: -20 to 70°C (no condensation or freezing)
Operating humidity rangeOperating/stored: 35 to 85% RH (no condensation)
Withstand voltage1,000 V AC or more (at 50/60 Hz) for 1 minute between terminals and housing
Insulation resistance2 MΩ or more (500 V DC measured via megohmmeter) between terminals and housing
Port sizeNil: Rc1/8, N type: NPT1/8, F type: G1/8*3
Lead wire with connector (individual wiring type)4 cores, oil-resistant cable (ø6, 5 m) with M12 4-pin pre-wired connector, Conductor O.D.: 0.90 mm, Insulator O.D.: 1.72 mm
Terminal block box (centralized wiring type)Front wiring (electrical entry ø21 [diameter 21 mm])
WeightIndividual wiring type (body only): 253 g, Centralized wiring type (body only): 250 g
Terminal block box: 205 g, Lead wire: 278 g, Connecting bracket with sealing for additional stations: 4 g
StandardsCE

*1: Refer to the chart showing the relationship between the nozzle diameter and detection distance in the manufacturer's catalog for the hysteresis.
*2: Refer to "Setting Procedure" in the manufacturer's catalog for details of the LED level meter.

Ordering Example

Without control unit

Centralized wiring

Centralized wiring

*ISA2-GE41P: 1 set (air catch sensor part number)

Individual wiring

Individual wiring

*ISA2-GE41N: 1 set (air catch sensor part number)

Centralized wiring / Supply port right

Centralized wiring / Supply port right

*ISA2-HE41P: 3 sets (air catch sensor part number)

The asterisk (*) is an embedded symbol. Prefix the part number of the air catch sensor with an asterisk (*).

With Control Unit

Centralized wiring / Supply port left

Centralized wiring / Supply port left

*ISA2-HE41P: 3 sets (air catch sensor part number)

Individual wiring / Supply port right

Individual wiring / Supply port right

*ISA2-GE41: 3 sets (air catch sensor part number)

The asterisk (*) is an embedded symbol. Prefix the part number of the air catch sensor with an asterisk (*).

Relation between Detection Distance and Hysteresis (Typical Example)

The data in the following charts are the characteristics of hysteresis at the detection distance.
The smaller the hysteresis, the better the sensitivity. In cases where the hysteresis exceeds 0.01 mm, the air catch sensor should be used to check the presence of the workpiece.

ISA2-G□□□□□

Detection nozzle: ø1.5 mm, Detection side piping: ø6 × ø4 tubing 5 m

Detection nozzle: ø1.5 mm, Detection side piping: ø6 × ø4 tubing 5 m

ISA2-H□□□□□

Detection nozzle: ø2 mm, Detection side piping: ø6 × 4 mm tubing 5 m

Detection nozzle: ø2 mm, Detection side piping: ø6 × 4 mm tubing 5 m

Parts List

Diagram

Diagram

Precautions

  • *See the manufacturer's catalog for product information other than the above.
  • *Product pictures are representations.
Part Number
ISA2-GE21P
ISA2-GE25P
ISA2-GE41P
ISA2-GE45P
ISA2-HE21P
ISA2-HE41P
ISA2-HE45
ISA2-HG25P
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMethod of electrical entry of lead wire Pressure gauge specification Detection distance
(mm)
Output specifications

3,762,000 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxSquare embedded type pressure gauge / 0.2 MPa/MPa (single notation)0.01 to 0.25NPN output

3,762,000 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxSquare embedded type pressure gauge / 0.2 MPa/MPa (single notation)0.01 to 0.25PNP output

3,762,000 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxSquare embedded type pressure gauge / 0.4 MPa/MPa (single notation)0.01 to 0.25NPN output

3,762,000 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxSquare embedded type pressure gauge / 0.4 MPa/MPa (single notation)0.01 to 0.25PNP output

3,762,000 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxSquare embedded type pressure gauge / 0.2 MPa/MPa (single notation)0.03 to 0.5NPN output

3,357,680 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxSquare embedded type pressure gauge / 0.4 MPa/MPa (single notation)0.03 to 0.5NPN output

3,659,273 IDR

1 Piece(s) 31 Day(s) Individual wiring / StraightSquare embedded type pressure gauge / 0.4 MPa/MPa (single notation)0.03 to 0.5PNP output

3,762,000 IDR

1 Piece(s) 31 Day(s) Centralized wiring / Terminal block boxRound pressure gauge / 0.2 MPa/MPa (single notation)0.03 to 0.5PNP output

Loading...

  1. 1
 

Basic Information

Piping specifications Rc 1/8

Tech Support