Miniature Basic Switch [VX]

Miniature Basic Switch [VX]
  • On Sale Till 31/03/2025

To detect light weight objects

[Features]
· Independent internal mechanism assures the high contact power even in load operation.
· It can be used in applications such as detection of light weight objects

PDF

Japanese Only

Dimensional Drawing of OMRON Micro Switches

Small basic switch VX Outline drawing-1
Small basic switch VX Outline drawing-2

Note 1. The dimensional tolerance of the parts not specified in the above external dimensions is ±0.4 mm.
Note 2. The operating characteristics are for operation in the A direction (↓).

Specification Table of OMRON Micro Switches

OMRON Micro Switches Performance

Micro Switches itemMicro Switches Model number
Model VX-5 seriesModel VX-01 series
Allowable Operating Speed0.1mm to 1m/s (for pin push button type)
Allowable operating frequencyMechanical600 times/min (for pin push button type)
Electrical60 times/min
Insulation resistance100MΩ or more (DC500V insulation resistance tester)
Contact resistance (initial value)30mΩ or less50mΩ or less
Withstand voltage*1Between same-polarity terminalsAC1,000V 50/60Hz 1min
Between live metal parts and earthAC1,500V 50/60Hz 1min
Between each terminal and non-current-carrying metal partsAC1,500V 50/60Hz 1min
Vibration*2malfunctionFrequency: 10 to 55 Hz, Double amplitude: 1.5 mm
Impact*2DurabilityUp to 400m/s2
malfunctionMaximum 100m/s2
DurabilityMechanicalOver 50 million times (60 times/min)Over 10 million times (60 times/min)
Micro Switches ElectricalOver 500,000 times (30 times/min)Over 1 million times (30 times/min)
Protective structureIEC IP40
Electric shock protection classClass I
PTI (Tracking Characteristics)175
Operating temperature range-25 to +105°C, 60% RH or less (but no freezing or condensation)
Operating humidity range85% RH or less (at +5 to +35°C)
massApprox. 6.2g (pin push button type)

Note: The above values are initial values.
*1. The withstand voltage is the value when a separator (see "Common Accessories for Microswitches") is used.
*2. The value is for the free position and full travel position for Micro Switches type, and for the full travel position for lever type. The contacts make or break within 1 ms.

Specification of OMRON Micro Switches

OMRON Micro Switches Operating Characteristics

Micro Switches ActuatorMicro Switches formatOperating characteristics
Force required for operationThe power of returnMovement up to operationMovement after actionDifferential movementOperating position
OF MaxRF MinPT MaxOT MinMD MaxOP
Micro Switches typeModel VX-5-1□2
Model VX-01-1□2
025N0.03N1.2mm1.0mm0.3mm14.7±0.4mm
Model VX-5-1□3
Model VX-01-1□3
0.49N0.05N
Hinge/
short lever type
(standard position)
Model VX-51-1□3
Model VX-011-1□3
0.49N0.04N (reference value)1.6mm0.8mm0.5mm15.2±0.5mm
Hinge
lever type
(standard position)
Model VX-52-1□3
Model VX-012-1□3
0.29N-4.0mm1.6mm0.8mm15.2±1.2mm
Hinge/
Long lever type
(standard position)
Model VX-53-1□3
Model VX-013-1□3
0.20N-9.0mm3.2mm2.0mm15.2±2.6mm
Hinge/
Long lever type
(K position)
Model VX-53K-1□3
Model VX-013K-1□3
0.12N-15.0mm5.0mm4.2mm15.2±4.4mm
Hinge
roller
lever type
(standard position)
Micro Switches Model VX-54-1□3
Micro Switches Model VX-014-1□3
0.29N0.02N4.0mm1.6mm0.8mm18.7±1.2mm
Hinge
roller
lever type
(K position)
Model VX-54K-1□3
Model VX-014K-1□3
0.18N(0.01N)7.2mm2.5mm2.0mm18.7±2.2mm
Hinge
roller
short lever type
(standard position)
Model VX-55-1□3
Model VX-015-1□3
0.59N0.04N (reference value)1.6mm0.8mm0.5mm20.7±0.6mm
Hinge
roller
lever type
(standard position)
Model VX-56-1□3
Model VX-016-1□3
0.29N-4.0mm1.6mm0.8mm20.7±1.2mm
Hinge
roller
lever type
(K position)
Model VX-56K-1□3
Model VX-016K-1□3
0.18N(0.01N)7.2mm2.5mm2.0mm20.7±2.2mm

Note 1. The RF reference value is the value when the lever is installed in a direction that does not apply weight to the Micro Switches.
Note 2. The operating characteristics are when it operates in the A direction (↓).

Model designation method of OMRON Micro Switches

OMRON Micro Switches Format Standards

Small basic switch VX type standard

OMRON Micro Switches Contact Specifications

Micro Switches 1c type (double throw type)
Micro Switches 1b type (normally closed)
Micro Switches 1a type (normally open)
Small basic switch VX 1c type (double throw type)
Small basic switch VX 1b type (normally closed)
Small basic switch VX 1a type (normally open)

OMRON Micro Switches Type/Shape

OMRON Micro Switches type/shape

Note: The above is for contact specifications 1c.

Technical Information of OMRON Micro Switches

OMRON Micro Switches Rating

OMRON Micro Switches Contact Specifications

Micro Switches formatMicro Switches Rated voltageMicro Switches item
Resistive Load
Micro Switches Model VX-5 seriesAC250V5A
Micro Switches Model VX-01 seriesAC125V0.1A
DC 30V0.1A
Micro Switches itemMicro Switches format
Model VX-5 seriesModel VX-01 series
contactspecificationrivetCrossbar
Micro Switches MaterialSilver AlloyGold alloy
Interval (standard value)0.5mm
Inrush currentNormally closedMaximum 15A-
Normally openMaximum 15A-
Minimum applicable load (reference value)*DC5V 160mADC5V 1mA
Note: The above ratings were tested under the following conditions:
     (1) Ambient temperature: 20±2°C
     (2) Ambient humidity: 65±5% RH
     (3) Operation frequency: 30 times/min.
* For the minimum applicable load,
  please refer to "●Using with Micro Switches" in "■Please Use Properly".

How to Use of OMRON Micro Switches

OMRON Micro Switches Mounting Hole Dimensions

Small basic switch VX mounting hole dimensions

OMRON Micro Switches Usage Notes

Micro Switches Regarding installation

The Micro Switches Use M3 screws for mounting and securely attach using flat washers, spring washers, etc. The tightening torque should be 0.39 to 0.59 N m.

 

Mounting direction

Regarding the actuator specifications, please install the actuator in a direction that does not apply its own weight to the Micro Switches.
This is a low Micro Switches and has a small return force, which may cause a return failure.

 

Regarding use with Micro Switches

Using a general-purpose switch when switching a Micro Switches circuit can cause poor contact. We recommend using the switch within the range of use, referring to the diagram below. Even if a microload type is used within the area shown inthe diagram below, if the load generates an inrush current when Micro Switches, contact wear will be rapid and durability will decrease, so insert a contact protection circuit as necessary. The minimum applicable load is the N-levelreference value. This represents the failure level at a confidence level of 60% (λ60
).  (JIS C5003)
λ60 = 0.5×10-6/times means that at a confidence level of 60%, failure is estimated to occur less than 1/2,000,000 times.

Use of the VX Miniature Basic Switch with Micro Load

Cautions and Prohibitions of OMRON Micro Switches

OMRON Micro Switches Safety Precautions

Micro Switches Handling

Do not subject the switch to strong shocks, as this is a low Micro Switches and may cause damage to the internal mechanism.

 

Regarding soldering

  • As a guideline, the soldering time for connecting to the soldering terminals should be less than 5 seconds with a soldering iron of 60W (tip temperature +250 to +350°C), and no external force should be applied for 1 minute after soldering
    . Use the minimum amount of flux possible. If flux gets inside the Micro Switches, it may cause contact failure.
  • Micro Switches Connection to #187 tab terminals
    : Use a #187 tab receptacle and insert it straight into the terminal.
    Applying excessive external force to the side or top/bottom of the terminal may cause deformation of the terminal and damage to the housing.
Part Number
VX-011-1A3
VX-013K-1C23
VX-014-3A3
VX-55-1C23
VX-56-1A2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Rated Operating Voltage
(V)
Lever Shape Type DC rated operating voltage
(V)
Plunger Shape Type Operating Temperature Range
(℃)
Motion to Switching P.T.
(mm)
Contact Type Contact Point Type Contact Material Mechanical Life
(10,000 times)
Rated Conductance Current
(A)
Current type Actuator type Specification of Terminal Lever mounting position Contact structure/specification Required force for push side, O.F. (detailed numerical values)
(N)

48,288 IDR

1 Piece(s) 68 Day(s) Lever Shape (push)-[Hinge Lever] Hinge Lever30--25~1051.6Single Pole Double Throw[Crossbar] CrossbarGold alloy10000.1AC/DCHinge, short lever typeTerminals With SolderLever set distant from plunger (Standard Position)1c0.49

44,418 IDR

1 Piece(s) 11 Day(s) or more Lever Shape (push)-[Hinge Lever] Hinge Lever30--25~10515.0Single Pole Double Throw[Crossbar] CrossbarGold alloy10000.1AC/DCHinge, long lever type#187 tab terminalLever set close to plunger (Position K)1c0.49

45,708 IDR

1 Piece(s) 11 Day(s) or more Lever Shape (push)-[Hinge Lever] Hinge Lever30--25~1054Single Pole Normally Open[Crossbar] CrossbarGold alloy10000.1AC/DCHinge, Earl, Lever typeTerminals With SolderLever set distant from plunger (Standard Position)1a0.49

54,223 IDR

1 Piece(s) 12 Day(s) Lever Shape (push)250[Hinge Lever] Hinge Lever---25~1051.6Single Pole Double ThrowRivetSilver alloy50005ACHinge, roller, short lever type#187 tab terminalLever set distant from plunger (Standard Position)1c0.49

40,000 IDR

1 Piece(s) Quote Lever Shape (push)250[Hinge Lever] Hinge Lever---25~1054Single Pole Double ThrowRivetSilver alloy50005ACHinge, roller, lever typeTerminals With SolderLever set distant from plunger (Standard Position)1c0.29

Loading...

  1. 1
 

Basic Information

Acquired Standards UL / CSA / EN Protection Structure IEC IP40 Body Material Thermoplastic
Force Required for Push Side O.F.(N) ~1 Mechanical Operation Frequency(times/min or Less) 600 Main Body External Dimension, Width W(mm) 10.3
Main Body External Dimension, Height H(mm) 15.9 Main Body External Dimension, Length L(mm) 27.8

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803