(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 24/11/2024 sampai dengan 6:00 pada tanggal 25/11/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 24/11/2024 to 6:00 (WIB) 25/11/2024. We apologize for the inconvenience.
  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Toyo Silicone S2 (TSIS2-25-L2)

Toyo Silicone S2 TSIS2-25-L2

Hose for piping in factory facilities and equipment. Combines a special double-layered woven structure and steel wire reinforcement for excellent durability.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

TSIS2-25-L2

 
Part Number
TSIS2-25-L2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSNominal I.D. d Outer Dia. D
(Ø)
Minimum Bending Radius
(mm)
Operating Pressure Range
(MPa)
Standard Length
(m)

12,891,236 IDR

1 Piece(s) 15 Day(s) or more 102539160-0.1~0.72

Loading...

  1. 1

Basic Information

Applicable Fluid / Usage Water / Chemical / Air / Foods / Oil(Mineral Oil) / Steam Cutting Service Usage Presence Properties Pressure Resistance / Heat resistant / Cold Resistance / Oil Resistance / Chemical Resistance / Low Elution / Transparency / Flexibility / Low Odor / Shape Retentivity / Vacuum / Other features
Hose Material Silicone Rubber Mounting Metal Fittings No Color Milky White
Operating Temperature Range(°C) -30::150

Frequently asked question (FAQ)

Question: Can steam be used as a fluid?
Answer: It is not a steam hose. Please use below 130°C and 0.2 MPa for brief sterilization work only; continuous use should be avoided.
Question: Can caustic soda be used as a fluid?
Answer: Do not pass caustic soda solution through the hose, as it will develop deterioration. However, solutions diluted to 2% to 3% may be used with no practical harm for the purpose of washing such as CIP cleaning. They are in fact used this way by CIP equipment manufacturers. Note that deterioration will proceed faster than with air or water as fluids

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)