Proximity Sensor for High Temperature and Cleaning Process [E2EH]

Proximity Sensor for High Temperature and Cleaning Process [E2EH]
  • On Sale Till 31/03/2025
  • Volume Discount

[Features]
· A proximity sensor. Ideal for the food and beverages industry.
· SUS316L body, IP69K, high temperature usage environment, detergent resistance

PDF

Japanese Only

Dimensional Drawing of OMRON Proximity Sensors

Pull-Out Cord Type OMRON Proximity Sensors (Shielded Type)

Connector Type OMRON Proximity Sensors (Shielded Type)

Specification Table of OMRON Proximity Sensors

OMRON Proximity Sensors Ratings/Performance

Proximity Sensors DC 2-wire type (E2EH-X□D□)

Proximity Sensors itemProximity Sensors format
Model E2EH-X3D□Model E2EH-X7D□Model E2EH-X12D□
Proximity Sensors sizeM12M18M30
shieldshield
Detection distance3mm7mm12mm
Set distance *10–2.4 mm0 to 5.6 mm0–9.6 mm
Hysteresis15% or less of detection distance
Detectable ObjectsMagnetic metals (The detection distance decreases for non-magnetic metals. See page 6 of the digital catalog for "Characteristics Data")
Standard detection objectIron 12 x 12 x 1 mmIron 21 x 21 x 1 mmIron 36 x 36 x 1 mm
Response frequency *2500Hz300Hz100Hz
Power supply voltage
(operating voltage range)
DC12-24V ripple (pp) 10% or less (DC10-32V, but up to 24V when over 100°C)
Leakage current0.8mA or less
Proximity Sensors Control OutputOpening and closing capacity3 to 100mA However, at +100 to +110°C, it is 3 to 50mA.
Residual voltage*3Polar type: 3 V or less, non-polar type (E2EH-X□D□-T) 5 V or less*3 (load current 100 mA, cord length 2 m)
Indicator LightD1 type: Operation indicator (red), setting indicator (yellow), D2 type: Operation indicator (yellow)
Proximity Sensors Operation mode
(when detecting object approaching)
D1 type: NO, D2 type: NC
For details, see the time chart of the "Input/Output stage circuit diagram" → page 7 of the digital catalog
Protection CircuitSurge absorption, load short circuit protection
Ambient Temperature RangeOperating: 0 to +100°C (0 to +110°C for 1,000 hours) *4
Storage: -25 to +70°C (no freezing or condensation)
Ambient Humidity RangeDuring operation and storage: 35 to 95% RH (but no condensation)
Temperature effectsThe change in detection distance in the temperature range of 0 to +70°C is within ±10% at 23°C.
The change in detection distance in the temperature range of +70 to +100°C is within ±15% at 23°C.
The change in detection distance in the temperature range of +100 to +110°C is within -15% to +20% at 23°C.
Voltage EffectsWithin ±10% of detection distance when the rated power supply voltage is within ±15% of the rated power supply voltage
Insulation Resistance50MΩ or more (at DC500V megger) Between all live parts and case
Withstand voltageAC1,000V 50/60Hz 1min Between live parts and case
Vibration (durability)10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability)1,000m/s2 10 times each in X, Y, and Z directions
Protective structureIEC standard IP67, DIN40050-9 standard IP69K *5
Proximity Sensors Connection methodPre-wired type (standard cord length 2m), connector type
Weight
(packaged)
Cable outletApprox. 80gApprox. 145gApprox. 220g
connectorApprox. 30gApprox. 55gApprox. 125g
Proximity Sensors MaterialCase, tightening nutStainless steel (SUS316L)
Detection surfacePBT
codeHeat-resistant PVC (with pull-out cord)
accessoriesoperating instructions

*1.For D1 type, use the yellow indicator light as a guide.
*2.The response frequency is an average value. Measurement conditions are as follows: The Proximity Sensors standard detection object is used, the detection object interval is twice that of the standard detection object, and the set distance is 1/2 thedetection distance.
*3.The residual voltage is 5V, so please check the interface conditions with the connected device before use. (→See page 9 of the digital catalog)
*4.Operation has been confirmed for 1,000 hours at 110°C. Do not repeatedly bend the cord in an environment of 100°C or higher.
*5.About the Proximity Sensors protection structure specification IP69KIP69K
    is a protection standard against high-temperature and high-pressure water, as stipulated in the German standard DIN 40050 PART9.
    80°C hot water is sprayed onto the test piece from a nozzle of the specified shape at a water pressure of 80 to 100 BAR. The water volume is 14 to 16 liters per minute.
    The distance between the test specimen and the nozzle of the Proximity Sensors is 10 to 15 cm, and the water is sprayed at horizontal directions of 0, 30, 60, and 90 degrees. The test specimen is rotated on a horizontal plane for 30seconds in each direction.

Proximity Sensors DC 3-wire type (E2EH-X□C□/B□)

Proximity Sensors itemProximity Sensors format
Model E2EH-X3C□/B□Model E2EH-X7C□/B□Model E2EH-X12C□/B□
Proximity Sensors sizeM12M18M30
shieldshield
Detection distance3mm±10%7mm±10%12mm±10%
Set distance0 to 2.4 mm0 to 5.6 mm0 to 9.6 mm
Hysteresis15% or less of detection distance
Detectable ObjectsMagnetic metals (The detection distance decreases for non-magnetic metals. See page 6 of the digital catalog for "Characteristics Data")
Standard detection objectIron 12 x 12 x 1 mmIron 21 x 21 x 1 mmIron 36 x 36 x 1 mm
Response frequency *1500Hz300Hz100Hz
Power supply voltage
(operating voltage range)
DC12-24V ripple (pp) 10% or less
(DC10-32V, but up to 24V when over 100°C)
Current consumption10mA or less
Control OutputOpening and closing capacityMaximum 100mA, but at +100 to +120°C, maximum 50mA
Residual voltage2V or less (load current 100mA, cord length 2m)
Indicator LightOperation indicator (yellow)
Proximity Sensors Operation mode
(when detecting object approaching)
C1 type: NO, C2 type: NC, B1 type: NO, B2 type: NCFor
details, refer to the time chart of the "Input/Output stage circuit diagram" → page 7 of the digital catalog.
Protection CircuitPower supply reverse polarity protection, surge absorption, load short circuit protection, output reverse polarity protection
Ambient Temperature RangeOperating: 0 to +100°C (0 to +120°C for 1,000 hours) *2
Storage: -25 to +70°C (no freezing or condensation)
Ambient Humidity RangeDuring operation and storage: 35 to 95% RH (but no condensation)
Temperature effectsThe change in detection distance in the temperature range of 0 to +70°C is within ±10% at 23°C.
The change in detection distance in the temperature range of +70 to +100°C is within ±15% at 23°C.
The change in detection distance in the temperature range of +100 to +120°C is within -15% to +20% at 23°C.
Voltage EffectsWithin ±10% of detection distance when the rated power supply voltage is within ±15% of the rated power supply voltage
Insulation Resistance50MΩ or more (at DC500V megger) Between all live parts and case
Withstand voltageAC1,000V 50/60Hz 1min Between live parts and case
Vibration (durability)10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability)1,000m/s2 10 times each in X, Y, and Z directions
Protective structureIEC standard IP67, DIN40050-9 standard IP69K
Proximity Sensors Connection methodPre-wired type (standard cord length 2m), connector type
Weight
(packaged)
Cable outletApprox. 80gApprox. 145gApprox. 220g
connectorApprox. 30gApprox. 55gApprox. 125g
Proximity Sensors MaterialCase, tightening nutStainless steel (SUS316L)
Detection surfacePBT
codeHeat-resistant PVC (with pull-out cord)
accessoriesoperating instructions

*1.The response frequency is an average value. Measurement conditions are: The Proximity Sensors standard detection object is used, the detection object interval is twice that of the standard detection object, and the set distance is 1/2 the detectiondistance.
*2.Operation has been confirmed for 1,000 hours at 120°C. Do not repeatedly bend the cord in an environment of 100°C or higher.

Part Number
E2EH-X3D1-T 2M
E2EH-X3D1-T 5M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSDetection distance L1 [classification]
(mm)
Operating Environment Screw Detection Head Size Head size Depth (range)
(mm)
Head size Depth
(mm)
Protection Structure (DIN40050-9) Power Type Output Mode Operation Mode Connection Method Connector pin arrangement Cable Length
(m)
Different Frequency Type Cable Specifications Included functions Combination amplifier/head Detection distance L1 details
(mm)

1,419,432 IDR

1 Piece(s) 8 Day(s) -~5Standard / Heat Resistant / Chemical Resistant Products / Cold ResistanceM1230.1~4038IP69KDirect Current 2-Wire TypeDC 2-wire non-polarNOPre-wired model-2StandardHeat-resistant PVC cord, φ4, 2-core/3-core--3

1,534,835 IDR

1,353,878 IDR

1 Piece(s) Same day -~5Standard / Heat Resistant / Chemical Resistant ProductsM1230.1~4038IP69KDirect Current 2-Wire TypeDC 2-wire non-polarNOPre-wired model① brown + V, ④ blue 0V5-Heat-resistant PVC cord, φ4, 2-core/3-core--3

Loading...

  1. 1
 

Basic Information

Shape Screw Type Detected Objects Magnetic Metal Shielded / Non-shielded Shield Type
Detection Direction Front Surface Case Material Stainless Steel (SUS316L) Detecting Surface Material Polybutylene Terephthalate
Amplifier Amplifier Built-in Type Acquired Standards CE / IEC Protection Structure (IEC) IP67
Types Intended for high-temperatures/cleaning processes Power Supply Voltage 12-24 VDC

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)