(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Penghentian penjualan kategori produk pneumatik Seri Ekonomi (E-series). Info Detail
    Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Control Equipment Standard Electromagnetic Valve F18 Series

Control Equipment Standard Electromagnetic Valve F18 Series

New version with greater ease of use and further enhanced power. *This series is having CAD data modified. Please wait till the corrections are done.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • When using the valve alone, select the option "Valve form symbol."
    Please check the catalog for details of options.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

F18T2-FJ5-PN DC24V

Product Specifications

Basic form and valve function

ItemBasic Form
F18T0F18T1
F18T2
F18T3
F18T4
F18T5
Number of positions2 Positions3 position
Number of ports5
Valve FunctionsFor Single SolenoidSingle solenoid, double solenoid dual-purpose typeClosed center, exhaust center, pressure center
ItemBasic Form
F18T0
F18T1
F18T2
F18T3
F18T4
F18T5
F18T0G
F18T1G
F18T2G
F18T3G
F18T4G
F18T5G
F18T0V
F18T1V
F18T2V
F18T3V
Operating fluidAir
Operating methodInternal Pilot TypeExternal Pilot Type (for original pressure)External pilot type (For vacuum)
Flow rate characteristicsSonic conductance C
dm^3 / (s*bar)^*1
3.6
Effective cross-sectional area [Cv value]^*2
mm^2
18 [1]
Piping connection diameter^*3ø8, ø10 dual-use fitting, Rc1/4M5 × 0.8, ø8, ø10 dual-use fitting, Rc1/4
LubricationNot required
Operating pressure rangeMain valve0.15 to 0.7 MPa0 to 0.7 MPa^*4-100 kPa to 0.15 MPa
External pilot0 to 0.7 MPa^*40.2 to 0.7 MPa
Proof pressure (MPa)1.05
Response time^*5
ON/OFF ms
12 V DC, 24 V DC25/35 or less15/70 or less25/35 or less15/70 or less25/35 or less15/70 or less
100 V AC25/35 or less15/70 or less25/35 or less15/70 or less25/35 or less15/70 or less
Maximum operating frequency Hz5
Minimum excitation time required for self-holding^*6 ms505050
Operating temperature range (atmosphere and operating fluid)°C+5 to +50
Impact resistance m/s^21,373
(Axial direction 294.2)
294.21,373
(Axial direction 294.2)
294.21,373
(Axial direction 294.2)
294.2
Mounting DirectionFree
  • *1: For details, see the section on flow rate characteristics in the digital catalog.
  • *2: *1: The value of the effective cross-sectional area is a calculated value, not an actual measurement value.
  • *3: For details, see the section on piping connection diameters in the digital catalog.
  • *4: When the main valve is 0.2 to 0.7 MPa, the external pilot pressure should be equal to or more than the main valve and 0.7 MPa or less.
  • *5: Value at air pressure 0.5 MPa. A maximum of 5 ms is added to the response time of the AC specification depending on the timing of the switching phase. When used as a single solenoid in the 2nd position, the 3rd position is the value from the valve neutral state of the closed center.
  • *6: When used as a double solenoid. Excluding T0.

Electrical Specifications

ItemRated Voltage
12 V DC24 V DC100 V AC
Operating voltage range V10.8 to 13.2 (12±13%)21.6 to 26.4 (24±13%)90 to 110 (100±13%)
Rated frequency Hz5060
Current Value (When rated voltage is applied): mA (r.m.s)Start1010
Holding76381010
Power Consumption W0.90.91.0VA
Allowable circuit leakage current mA4.02.02.0
Insulation TypeType B
Insulation resistance MΩ100 or More
Led Indicator Color14 (SA): Red, 12 (SB): Green14 (SA): Red, 12 (SB): Green14 (SA): Red, 12 (SB): Green
Surge Protection (Standard Equipment)Flywheel diodeBridge diode 
Single solenoid status

Single solenoid status

Double solenoid status

Double solenoid status

Example of use

Example: External appearance with ø6 (6 mm in diameter) tubes connected

Example: External appearance with ø6 (6 mm in diameter) tubes connected

Example: External appearance with ø4 (4 mm in diameter) tubes connected

Example: External appearance with ø4 (4 mm in diameter) tubes connected

Product features details

A new shape that has been further enhanced by the thorough pursuit of ease of use
Uses reducing size dual-purpose fittings

Secret story of development

 

It is a product with combining design know-how and production technology cultivated since the manufacturer founding to meet customer needs, and it is developed after undergoing strict inspection.

Part Number
F18T2-FJ5-PN DC24V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

1,886,868 IDR

1 Piece(s) 25 Day(s)

Loading...

  1. 1

Basic Information

Type Electromagnetic Valve Application Unit for manifold mounted Number of Ports 5-port valve
Mounting Orientation Manifold base Specifications Oil-Free Number of Solenoids Double
Switching Type 2-position exhaust Status at Power Off Self-holding Voltage DC24V
Pipe Port Type One-Touch Pipe Manual Switch(Ø) 50 to 100 Plumbing Direct piping
Driving Type Pilot-operated Spool CV Value 0.57 Connecting Tube Diameter φ8
Seal Type Soft seal Pressure Rating(MPa) 0.15 to 0.7 Pilot Air Supply Internal
Other specifications Output port with single fitting block Operation Mode Internal Pilot Type Wiring Type PN
2 Position· Single Solenoid Specifications Form for Both Single / Double Manual Mechanism Manual button Independent Air Supply / Exhaust Specifications, Stop Valve Without spacer
Split No split

Please check the type/dimensions/specifications of the part F18T2-FJ5-PN DC24V in the Control Equipment Standard Electromagnetic Valve F18 Series series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)