(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
This translation is a Google translation Terjemahan ini adalah terjemahan Google
Electromagnetic switch for coil voltage 200 V AC. The open-close lifespan of this product is among the best in the world.
Part Number
Configured Part Number is shown.
KHK32-AC200V-5
Frame Size (AF) | Coil Voltage | Auxiliary Contact | Motor Capacity (KW) | Thermal Relay Model | Setting Range (A) | Model |
6 | 200 VAC | 1a | 0.05 | SMR-12-0.52 | 0.4 ~ 0.63 | KHK6-AC200V-0.52 |
0.1 | SMR-12-0.82 | 0.63 ~ 1 | KHK6-AC200V-0.82 | |||
0.2 | SMR-12-1.3 | 1 ~ 1.6 | KHK6-AC200V-1.3 | |||
0.4 | SMR-12-2.1 | 1.6 ~ 2.5 | KHK6-AC200V-2.1 | |||
0.75 | SMR-12-3.3 | 2.5 ~ 4 | KHK6-AC200V-3.3 | |||
1 | SMR-12-5 | 4 ~ 6 | KHK6-AC200V-5 | |||
1.5 | SMR-12-6.5 | 5 ~ 8 | KHK6-AC200V-6.5 | |||
1.5 | SMR-12-7.5 | 6 ~ 9 | KHK6-AC200V-7.5 | |||
2.2 | SMR-12-8.5 | 7 ~ 10 | KHK6-AC200V-8.5 | |||
9 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK9-AC200V-0.52 | |
0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK9-AC200V-0.82 | |||
0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK9-AC200V-1.3 | |||
0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK9-AC200V-2.1 | |||
0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK9-AC200V-3.3 | |||
1 | SMR-32-5 | 4 ~ 6 | KHK9-AC200V-5 | |||
1.5 | SMR-32-6.5 | 5 ~ 8 | KHK9-AC200V-6.5 | |||
1.5 | SMR-32-7.5 | 6 ~ 9 | KHK9-AC200V-7.5 | |||
2.2 | SMR-32-8.5 | 7 ~ 10 | KHK9-AC200V-8.5 | |||
3.7 | SMR-32-11 | 9 ~ 13 | KHK9-AC200V-11 | |||
3.7 | SMR-32-15 | 12 ~ 18 | KHK9-AC200V-15 | |||
5.5 | SMR-32-19 | 16 ~ 22 | KHK9-AC200V-19 | |||
5.5 | SMR-32-21.5 | 18 ~ 25 | KHK9-AC200V-21.5 | |||
7.5 | SMR-32-27 | 22 ~ 32 | KHK9-AC200V-27 | |||
13 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK12-AC200V-0.52 | |
0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK12-AC200V-0.82 | |||
0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK12-AC200V-1.3 | |||
0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK12-AC200V-2.1 | |||
0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK12-AC200V-3.3 | |||
1 | SMR-32-5 | 4 ~ 6 | KHK12-AC200V-5 | |||
1.5 | SMR-32-6.5 | 5 ~ 8 | KHK12-AC200V-6.5 | |||
1.5 | SMR-32-7.5 | 6 ~ 9 | KHK12-AC200V-7.5 | |||
2.2 | SMR-32-8.5 | 7 ~ 10 | KHK12-AC200V-8.5 | |||
3.7 | SMR-32-11 | 9 ~ 13 | KHK12-AC200V-11 | |||
3.7 | SMR-32-15 | 12 ~ 18 | KHK12-AC200V-15 | |||
5.5 | SMR-32-19 | 16 ~ 22 | KHK12-AC200V-19 | |||
5.5 | SMR-32-21.5 | 18 ~ 25 | KHK12-AC200V-21.5 | |||
7.5 | SMR-32-27 | 22 ~ 32 | KHK12-AC200V-27 | |||
18 | 200 VAC | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK18-AC200V-0.52 |
0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK18-AC200V-0.82 | |||
0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK18-AC200V-1.3 | |||
0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK18-AC200V-2.1 | |||
0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK18-AC200V-3.3 | |||
1 | SMR-32-5 | 4 ~ 6 | KHK18-AC200V-5 | |||
1.5 | SMR-32-6.5 | 5 ~ 8 | KHK18-AC200V-6.5 | |||
1.5 | SMR-32-7.5 | 6 ~ 9 | KHK18-AC200V-7.5 | |||
2.2 | SMR-32-8.5 | 7 ~ 10 | KHK18-AC200V-8.5 | |||
3.7 | SMR-32-11 | 9 ~ 13 | KHK18-AC200V-11 | |||
3.7 | SMR-32-15 | 12 ~ 18 | KHK18-AC200V-15 | |||
5.5 | SMR-32-19 | 16 ~ 22 | KHK18-AC200V-19 | |||
5.5 | SMR-32-21.5 | 18 ~ 25 | KHK18-AC200V-21.5 | |||
7.5 | SMR-32-27 | 22 ~ 32 | KHK18-AC200V-27 | |||
22 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK22-AC200V-0.52 | |
0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK22-AC200V-0.82 | |||
0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK22-AC200V-1.3 | |||
0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK22-AC200V-2.1 | |||
0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK22-AC200V-3.3 | |||
1 | SMR-32-5 | 4 ~ 6 | KHK22-AC200V-5 | |||
1.5 | SMR-32-6.5 | 5 ~ 8 | KHK22-AC200V-6.5 | |||
1.5 | SMR-32-7.5 | 6 ~ 9 | KHK22-AC200V-7.5 | |||
2.2 | SMR-32-8.5 | 7 ~ 10 | KHK22-AC200V-8.5 | |||
3.7 | SMR-32-11 | 9 ~ 13 | KHK22-AC200V-11 | |||
3.7 | SMR-32-15 | 12 ~ 18 | KHK22-AC200V-15 | |||
5.5 | SMR-32-19 | 16 ~ 22 | KHK22-AC200V-19 | |||
5.5 | SMR-32-21.5 | 18 ~ 25 | KHK22-AC200V-21.5 | |||
7.5 | SMR-32-27 | 22 ~ 32 | KHK22-AC200V-27 | |||
32 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK32-AC200V-0.52 | |
0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK32-AC200V-0.82 | |||
0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK32-AC200V-1.3 | |||
0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK32-AC200V-2.1 | |||
0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK32-AC200V-3.3 | |||
1 | SMR-32-5 | 4 ~ 6 | KHK32-AC200V-5 | |||
1.5 | SMR-32-6.5 | 5 ~ 8 | KHK32-AC200V-6.5 | |||
1.5 | SMR-32-7.5 | 6 ~ 9 | KHK32-AC200V-7.5 | |||
2.2 | SMR-32-8.5 | 7 ~ 10 | KHK32-AC200V-8.5 | |||
3.7 | SMR-32-11 | 9 ~ 13 | KHK32-AC200V-11 | |||
3.7 | SMR-32-15 | 12 ~ 18 | KHK32-AC200V-15 | |||
5.5 | SMR-32-19 | 16 ~ 22 | KHK32-AC200V-19 | |||
5.5 | SMR-32-21.5 | 18 ~ 25 | KHK32-AC200V-21.5 | |||
7.5 | SMR-32-27 | 22 ~ 32 | KHK32-AC200V-27 | |||
55 | 1a1b | 3.7 | SMR-63-15S | 12 ~ 18 | KHK50-AC200V-15S | |
5.5 | SMR-63-19S | 16 ~ 22 | KHK50-AC200V-19S | |||
5.5 | SMR-63-21.5S | 18 ~ 25 | KHK50-AC200V-21.5S | |||
7.5 | SMR-63-30S | 24 ~ 36 | KHK50-AC200V-30S | |||
7.5 | SMR-63-34S | 28 ~ 40 | KHK50-AC200V-34S | |||
11 | SMR-63-42S | 34 ~ 50 | KHK50-AC200V-42S | |||
15 | SMR-63-55S | 45 ~ 65 | KHK50-AC200V-55S | |||
65 | 1a1b | 3.7 | SMR-63-15S | 12 ~ 18 | KHK65-AC200V-15S | |
5.5 | SMR-63-19S | 16 ~ 22 | KHK65-AC200V-19S | |||
5.5 | SMR-63-21.5S | 18 ~ 25 | KHK65-AC200V-21.5S | |||
7.5 | SMR-63-30S | 24 ~ 36 | KHK65-AC200V-30S | |||
7.5 | SMR-63-34S | 28 ~ 40 | KHK65-AC200V-34S | |||
11 | SMR-63-42S | 34 ~ 50 | KHK65-AC200V-42S | |||
15 | SMR-63-55S | 45 ~ 65 | KHK65-AC200V-55S |
Frame Size | 18AF | 22AF | 40AF | 65AF | ||||||
Model | KHK 6 | KHK 9 | KHK 12 | KHK 18 | KHK 22 | KHK 32 | KHK 50 | KHK 65 | ||
Number of Phases | 3 | 3 | 3 | 3 | ||||||
Rated Voltage | 690V | 690V | 690V | 690V | ||||||
Rated Insulation Voltage | 690V | 690V | 1000V | 1000V | ||||||
Rated Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | ||||||
Rated Impulse Voltage | 6 KV | 6 KV | 8 KV | 8 KV | ||||||
Switching Frequency (operations / hour) AC3 Grade | 1800 | 1800 | 1800 | 1800 | ||||||
Mechanical Life (10K Times) | 1500 | 1500 | 1200 | 1200 | ||||||
Electrical Life (10K Times) | 250 | 250 | 200 | 200 | ||||||
AC Class 1 | A | 25 | 25 | 25 | 32 | 40 | 50 | 70 | 100 | |
AC Class 3 200 / 240 V | KW | 2.2 | 2.5 | 3.5 | 4.5 | 5.5 | 7.5 | 15 | 18.5 | |
A | 9 | 11 | 13 | 18 | 22 | 32 | 55 | 65 | ||
380/440V | KW | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 22 | 30 | |
A | 7 | 9 | 12 | 18 | 22 | 32 | 50 | 65 | ||
500/550V | KW | 3 | 4 | 7.5 | 7.5 | 15 | 18.5 | 30 | 33 | |
A | 6 | 7 | 12 | 13 | 20 | 28 | 43 | 60 | ||
690V | KW | 3 | 4 | 7.5 | 7.5 | 15 | 18.5 | 30 | 33 | |
A | 4 | 6 | 9 | 9 | 18 | 20 | 28 | 35 | ||
UL Rated | Continuous Current | A | 25 | 25 | 25 | 40 | 40 | 50 | 70 | 100 |
Single-phase | 110 ~ 120V | 0.5 | 0.5 | 0.75 | 1 | 2 | 2 | 3 | 5 | |
220 ~ 240V | 1.5 | 1.5 | 2 | 3 | 3 | 5 | 10 | 15 | ||
Three-phase | 200 ~ 208V | 2 | 2 | 3 | 5 | 7.5 | 7.5 | 20 | 25 | |
220 ~ 240V | 3 | 3 | 5 | 7.5 | 10 | 10 | 25 | 30 | ||
440 ~ 480V | 5 | 5 | 7.5 | 10 | 15 | 20 | 40 | 50 | ||
550 ~ 600V | 7.5 | 7.5 | 10 | 15 | 20 | 25 | 50 | 60 | ||
Coil Voltage AC | Weight | Kg | 0.43 | 0.54 | 0.72 | 1.36 | 1.38 | |||
Coil Voltage DC | Weight | Kg | 0.6 | 0.68 | 0.94 | 1.61 | 1.63 |
Ambient Temperature | Reference 20°C, -10°C ~ 40°C |
(Maximum 35°C daily average air temperature, maximum 25°C annual average air temperature) | |
Maximum Board Internal Temperature | 55°C |
Take care, as operational characteristics of electromagnetic contacts and thermal relays can be affected by the ambient temperature. | |
Relative Humidity | 45 ~ 85% RH, no condensation or freezing. |
Altitude | 2,000 m or lower |
Vibration | 10 ~ 55 Hz 19.6 m / s2 or lower |
Impact | 49 m / s2 or lower |
Atmosphere | Excessive amount of dust, smoke, corrosive gases, flammable gas, moisture, or salt must not be present. Extended use in sealed conditions may lead to possible contact defects. |
Part Number |
---|
KHK32-AC200V-5 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Motor Capacity VAC 200–220 Class (kW/A) | Auxiliary Contact | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Motor capacity AC 200 V (kW/A) | Setting range (A) | Rated current (A) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
664,829 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 1 | 1a1b | 139.4 | 45 | 90 | 1 | 4 ~ 6 | 32 |
Loading...
Electromagnetic Switch
Electromagnetic Switch
Frame Size | 18AF | 22AF | 40AF | 65AF | ||||
---|---|---|---|---|---|---|---|---|
Model | KHK6 | KHK9 | KHK12 | KHK18 | KHK22 | KHK32 | KHK50 | KHK65 |
Number of Phases | 3 | 3 | 3 | 3 | ||||
Rated Voltage | 690 V | 690 V | 690 V | 690 V | ||||
Rated Insulation Voltage | 690 V | 690 V | 1,000 V | 1,000 V | ||||
Rated Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | ||||
Rated Impulse Voltage | 6 KV | 6 KV | 8 KV | 8 KV | ||||
Switching Frequency (times / hour), AC Class 3 | 1,800 | 1,800 | 1,800 | 1,800 | ||||
Mechanical Life (10,000 times) | 1,500 | 1,500 | 1,200 | 1,200 | ||||
Electrical Life (10,000 times) | 250 | 250 | 200 | 200 | ||||
AC - Class 1 A | 25 | 25 | 25 | 32 | 40 | 50 | 70 | 100 |
AC - Class 3 200 / 240 V KW | 2.2 | 2.5 | 3.5 | 4.5 | 5.5 | 7.5 | 15 | 18.5 |
A | 9 | 11 | 13 | 18 | 22 | 32 | 55 | 65 |
380 / 440 V KW | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 22 | 30 |
A | 7 | 9 | 12 | 18 | 22 | 32 | 50 | 65 |
500 / 550 V KW | 3 | 4 | 7.5 | 7.5 | 15 | 18.5 | 30 | 33 |
A | 6 | 7 | 12 | 13 | 20 | 28 | 43 | 60 |
690 V KW | 3 | 4 | 7.5 | 7.5 | 15 | 18.5 | 30 | 33 |
A | 4 | 6 | 9 | 9 | 18 | 20 | 28 | 35 |
UL Rated, Continuous Current, A | 25 | 25 | 25 | 40 | 40 | 50 | 70 | 100 |
Single Phase 110 ~ 120 V | 0.5 | 0.5 | 0.75 | 1 | 2 | 2 | 3 | 5 |
220 ~ 240 V | 1.5 | 1.5 | 2 | 3 | 3 | 5 | 10 | 15 |
Three Phase 200 ~ 208 V | 2 | 2 | 3 | 5 | 7.5 | 7.5 | 20 | 25 |
220 ~ 240 V | 3 | 3 | 5 | 7.5 | 10 | 10 | 25 | 30 |
440 ~ 480 V | 5 | 5 | 7.5 | 10 | 15 | 20 | 40 | 50 |
550 ~ 600 V | 7.5 | 7.5 | 10 | 15 | 20 | 25 | 50 | 60 |
Coil Voltage AC Weight Kg | 0.43 | 0.54 | 0.72 | 1.36 | 1.38 | |||
Coil Voltage DC Weight, Kg | 0.6 | 0.68 | 0.94 | 1.61 | 1.63 |
Ambient Temperature | Standard temperature at 20°C, -10°C ~ 40°C |
---|---|
(Maximum Daily Average Ambient Temperature 35°C, Maximum Annual Average Ambient Temperature 25°C) | |
Maximum Internal Panel Temperature | 55°C |
Note that the operating properties of the electromagnetic connector and thermal relay are influenced by ambient temperature. | |
Relative Humidity | 45 ~ 85% RH, no condensation or freezing. |
Altitude | 2,000 m or lower |
Vibration | 10 ~ 55 Hz 19.6 m/s2 or lower |
Impact | 49 m/s2 or lower |
Ambient Atmosphere | The ambient atmosphere must not contain excessive dust, smoke, corrosive or combustible gas, moisture, or salt content. Further, prolonged operation while sealed may cause problems such as contact failure. |
Operating Method | Irreversible type | Coil rated voltage(V) | AC 200 | Number of Poles | 3 |
---|---|---|---|---|---|
Representative Standard | CE | Other standards (IEC) | ○ | Other standards (KEMA) | ○ |
Please check the type/dimensions/specifications of the part KHK32-AC200V-5 in the 200 VAC Irreversible Electromagnetic Switch Coil series.
Part Number |
---|
KHK12-AC200V-15 |
KHK12-AC200V-19 |
KHK12-AC200V-2.1 |
KHK32-AC200V-6.5 |
KHK32-AC200V-7.5 |
KHK32-AC200V-8.5 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Motor Capacity VAC 200–220 Class (kW/A) | Auxiliary Contact | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Motor capacity AC 200 V (kW/A) | Setting range (A) | Rated current (A) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
377,488 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 3.7 | 1a1b | 129.9 | 45 | 90 | 3.7 | 12 ~ 18 | 12 | |
377,488 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 5.5 | 1a1b | 129.9 | 45 | 90 | 5.5 | 16 ~ 22 | 12 | |
377,488 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 0.4 | 1a1b | 129.9 | 45 | 90 | 0.4 | 1.6 ~ 2.5 | 12 | |
664,829 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 1.5 | 1a1b | 139.4 | 45 | 90 | 1.5 | 5 ~ 8 | 32 | |
664,829 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 1.5 | 1a1b | 139.4 | 45 | 90 | 1.5 | 6 ~ 9 | 32 | |
664,829 IDR | 1 Piece(s) | Available | 8 Day(s) or more | 2.2 | 1a1b | 139.4 | 45 | 90 | 2.2 | 7 ~ 10 | 32 |
How can we improve?Bagaimana Kami bisa meningkatkan Pelayanan?
How can we improve?Bagaimana Kami bisa meningkatkan Pelayanan?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy Walaupun Kami tidak dapat langsung menjawab saran yang ditulis di lembar ini, informasinya akan kami review untuk peningkatan pelayanan dikemudian hari
Kebijakan Privacy
Thank you for your cooperation.Terima kasih atas kerjasama anda.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy Walaupun Kami tidak dapat langsung menjawab saran yang ditulis di lembar ini, informasinya akan kami review untuk peningkatan pelayanan dikemudian hari
Silahkan pergunakan Forms Permintaan.
Kebijakan Privacy